ARA-X4 Wearable Multi-Gas Detector

The ARA-X4 wearable 4 gas monitor is a rugged, cost-effective 4 gas monitor designed to protect workers from oxygen, toxic and flammable gas hazards. This wearable multi gas detector monitors up to four gases simultaneously, providing continuous personal protection across demanding industrial environments, including confined spaces.

  • Configurable sensor options, including leaded or lead-free oxygen options
  • Real-time readings with audible, visual and vibration alarms
  • Features an IP67-rated enclosure for dust and water protection
  • Supports easy maintenance with an accessible filter design
  • Offers event logging and optional automated bump testing and calibration
  • Meets ATEX and IECEx requirements
  • ATEX hazardous area certification symbol.ATEX_logo
  • IECEx certification logo.Logo-IECEx-TM-500px
  • QPS certified product mark.QPS-C-C-255

Multiple Sensor Options

Flexibility to choose O2 (leaded or lead-free), CO, H2S, LEL (Pellistor or IR), HCN and SO2 sensors to suit specific application needs.

Instrument Warranty

Reliable instrument performance backed by a 5-year warranty.

Flip Screen

LCD screen features a ‘flip’ function to flip the screen based on instrument orientation, ensuring easy readings.
Measurement & Performance
SpecificationDetails
Gas Sensor OptionsElectrochemical:
CO H2S DualTox (CO/H2S)
O2 (lead or lead-free options)
SO2
HCN
Flammable Sensors:
LEL Pellistor (CH4)
LEL NDIR (CH4)
Gas Sensor Detection RangesCO: 0 to 500 ppm
H2S: 0 to 100 ppm
O2: 0 to 25%
SO2: 0 to 20 ppm
HCN: 0 to 30 ppm
LEL: 0 to 100% LEL
Gas Sensor Response TimesO2 (L): T90 <15 sec
O2 (LF): T90 <20 sec
CO: T90 <30 sec
H2S: T90 <30 sec
DualTox CO: T90 <40 sec
DualTox H2S: T90 <30 sec
LEL (CAT): T90 <30 sec
LEL (IR): T90 <45 sec
HCN: T90 <75 sec SO2: T90 <60 sec
Sampling MethodDiffusive
DisplayLiquid Crystal Display: 45 x 45 mm, Internal backlight
AlarmsAudible, visual, vibrating
Alarm ConditionsLow, High, TWA, STEL, OL, -OL, Multi alarm
Operation2-button operation

Accessories

ItemPart numberDescription
View image: ARA-X Docking Station
ARA-X Docking Station
926200

Docking station for charging, bump testing and calibrating ARA-X4

View image: ARA-X4 Car Charger
ARA-X4 Car Charger
926242

Vehicle charger for powering or charging the ARA-X4 while travelling

Spares

ItemPart numberDescription
View image: ARA IR Link and USB Cable
ARA IR Link and USB Cable
908201

Infrared communication link and USB cable for connecting compatible ARA range detectors to a computer

View image: ARA-X4 Calibration Cap
ARA-X4 Calibration Cap
926243

Calibration cap for applying test gas during bump tests and calibration of the ARA-X4

ARA-X4 Filter Assembly (pack of 5)
926263

Replacement filter assemblies for protecting the multi gas detector gas inlet from dust and debris

ARA-X4 Gas Plate
926206

Replacement gas plate for the ARA-X4 detector assembly

ARA-X4 LCD
926249

Replacement LCD screen for the multi gas detector

ARA-X4 Screw Kit
926252

Replacement screw set for servicing the multi gas detector enclosure

ARA-X4 is a wearable multi gas detector designed to help protect workers in hazardous environments by continuously monitoring oxygen, toxic and flammable gas hazards. This compact 4 gas monitor can be configured with different sensor options to suit specific workplace risks and applications.

ARA-X4 can monitor up to four gases simultaneously, depending on the selected sensor configuration. Available electrochemical sensor options include oxygen (O₂), carbon monoxide (CO), hydrogen sulphide (H₂S), a combined CO/H₂S Dual Tox sensor, hydrogen cyanide (HCN) and sulphur dioxide (SO₂). Flammable gas monitoring is available using an LEL Pellistor or LEL NDIR sensor.

The gases monitored depend on the selected instrument configuration; a single ARA-X4 does not monitor every gas listed above simultaneously.

ARA-X4 is suitable for industries where workers may be exposed to oxygen-deficient, toxic or flammable atmospheres. Applications include oil and gas, petrochemical, pharmaceutical, maritime, utilities, wastewater, manufacturing and emergency response.

The sensor configuration should be selected according to the hazards identified by the workplace risk assessment.

ARA-X4 can be worn as a diffusion-based personal gas monitor during confined-space work, providing continuous monitoring of the gases included in the selected sensor configuration.

The current model does not include an integrated pump and therefore cannot draw remote samples for pre-entry testing. A pumped model is pending and further information on its availability will be provided once confirmed.

Where remote sampling is required, users should select a suitable pumped gas detector and sampling system in accordance with their risk assessment, confined-space procedure and applicable guidance.

ARA-X4 offers configurable oxygen, toxic gas and flammable gas sensors, including a choice of leaded or lead-free oxygen sensor. This flexibility allows the wearable 4 gas monitor to be configured for different workplace hazards and operating environments.

The required gases, measurement ranges and sensor compatibility should be confirmed when selecting the instrument.

Yes. ARA-X4 holds ATEX and IECEx certification for use in approved potentially explosive atmospheres.

Always check the certification marked on the instrument and detailed in its technical documentation to confirm that the selected configuration is suitable for the intended hazardous area, location and operating conditions.

ARA-X4 is designed to be worn within the user’s breathing zone to provide continuous personal monitoring. The instrument should be securely attached and positioned in accordance with the product manual and applicable workplace safety procedures.

ARA-X4 has an accessible filter design that enables quick replacement and simplifies routine maintenance. The optional docking station supports automated bump testing and calibration, helping organisations maintain consistent instrument performance and test records.

Users should follow the maintenance, bump-testing and calibration procedures specified in the product manual and their site requirements.

Yes. ARA-X4 records event logs when alarms are triggered. These records can support incident investigations, exposure reviews, safety audits and compliance reporting.

Refer to the technical documentation for details of the information recorded, storage capacity and data-download process.

ARA-X4 is supplied with a five-year standard instrument warranty. Sensor warranty periods may vary depending on the selected sensor type and configuration.

Refer to the applicable warranty terms or contact ION Science for full details of the coverage, conditions and exclusions.

Where to Buy the ARA-X4 Multi-Gas Detector

ARA-X4 is available through ION Science’s global network of authorised distributors. Use the map below to find your nearest distributor and access local product, purchasing and technical support.

Sales Centre OnlySales and Service CentreMultiple locations

Talk to Our Gas Detection Team

Whether you need a single ARA-X4 wearable gas detector or are standardising personal gas monitoring across multiple sites, our team can help you select the appropriate sensor configuration, accessories and docking solution for your application.

Enquire about ARA-X4 Wearable Multi-Gas Detector

Loading enquiry form…

Contact ION Science

Loading enquiry form…

Newsletter sign up

Loading enquiry form…

Warranty registration

Loading enquiry form…

Contact support

Loading enquiry form…