Tiger XTL Portable PID VOC Detector
- The ION Science Tiger XTL is a cost-effective portable PID detector designed for reliable volatile organic compound (VOC) monitoring across routine industrial applications.
This portable PID gas detector combines patented photoionisation detection (PID) technology with straightforward operation and rugged construction.
- Reliable ppm VOC detection for routine monitoring
- Patented Fence Electrode Technology to minimise humidity and contamination effects
- Up to 24 hours of battery life
- Intrinsically safe for hazardous environments
- Large backlit display and integrated torch
- Rugged construction for demanding industrial environments
- Economical replacement lamps, filters and components for low-maintenance operation
ATEX_logo
Logo-IECEx-TM-500px
SGS logo_digital_80px
Low Cost, High Performance
Simple, One-Handed Operation
Leading Warranty
*2 years instrument warranty when registered on the ION Science website within one month of purchase.
| Specification | Details |
|---|---|
| Range | 0.1 ppm to 5,000 ppm |
| Minimum Resolution | 0.1 ppm |
| Accuracy | ± 5% display reading or ± one-digit (at calibration point) |
| Response Time | T90 < 2 seconds |
| Flow Rate | ≥ 220 mL/min |
| Alarms | Flashing LEDs amber (low alarm) red (high alarm) Sounder 95 dBA at 300 mm (12”) Vibration on alarm |
| Operation | 6-button operation |
| Specification | Details |
|---|---|
| Battery | Li-ion battery |
| Operating Time | Up to 24 hours |
| Charging Time | Up to 8 hours |
| Specification | Details |
|---|---|
| Operating Temperature | -20 ºC to +60 ºC (-4 ºF to +140 ºF) |
| Humidity | 0 - 99% Relative Humidity (non-condensing) |
| Ingress Protection Rating | IP65 |
| Weight | 870 g (1.9 lb) |
| Dimensions (with probe) | 91 × 370 × 60mm (3.5 × 14.5 x 2.3 in) |
| Specification | Details |
|---|---|
| ATEX | II 1G Ex ia IIC T4 Ga SGS25ATEX0002X SGS25ATEX0003X SGS25ATEX0004X |
| IECEx | IECEx SGS 25.0002X |
| EMC | EN61326-1:2013, EN50270:2015 & CFR 47:2008 Class A |
| North American Hazardous Location | Class 1 Division 1. Groups A, B, C & D, T4 SGSNA/25/CA/00001X |
- Tiger XTL Brochure English
- Tiger XTL Brochure Chinese
- Tiger XTL Brochure French
- Tiger XTL Brochure German
- Tiger XTL Brochure Italian
- Tiger XTL Brochure Spanish
- Tiger XTL User Manual English
- Tiger XTL User Manual Chinese
- Tiger XTL User Manual French
- Tiger XTL User Manual German
- Tiger XTL User Manual Italian
- Tiger XTL User Manual Spanish
- Tiger LT PC Software V1.2.0.13
Tiger XTL Handheld VOC Gas Detector
Unboxing the Tiger XTL VOC Gas Detector
The Tiger XT Range of Handheld VOC Gas Detectors
How Photoionisation Detection (PID) Works
Accessories
| Item | Part number | Description |
|---|---|---|
View image: Car Charger Lead
Car Charger Lead
|
1/jawu-01 | Vehicle charging lead for powering or charging the Tiger XT while travelling |
View image: Multi Adaptor with Pipe Connector
Multi Adaptor with Pipe Connector
|
A-912338 | This adaptor features a quick-release connector for attaching longer lengths of tubing with a 4 mm internal diameter and 6 mm external diameter |
View image: Multi Adaptor with Probe Extension 1000mm
Multi Adaptor with Probe Extension 1000mm
|
A-912337 | Flexible 1000mm probe extension for sampling hard to reach areas with the Tiger XT and Tiger XTL |
View image: Multi Adaptor with Probe Extension 300mm
Multi Adaptor with Probe Extension 300mm
|
A-912336 | Flexible probe attaches to the Tiger XT range and is used for hard to reach spaces. |
View image: Tiger XT Container Probe
Tiger XT Container Probe
|
A-912339 | Designed for reliable remote sampling in demanding applications |
View image: Tiger XT Range Accessory Kit
Tiger XT Range Accessory Kit
|
A-912300 | Contains a PTFE filter discs, sensor O-ring seal, carbon filter, lamp cleaning compound, cal adaptor, PID stack removal tool, lanyard, and battery lid catch for quick, simple maintenance. |
View image: Tiger XTL Fire Investigation Kit
Tiger XTL Fire Investigation Kit
|
TXLLSRBMP-0000 | A complete accessory kit for the Tiger XTL, supplied with a premium carrying case, rechargeable battery pack, charger assembly, multi-region mains adaptor, car charger lead, PID response check pen, 1m flexi probe, pack of 10 PTFE filters, exhaust barb and USB cable. |
Spares
| Item | Part number | Description |
|---|---|---|
View image: Electrode Stack Orange
Electrode Stack Orange
|
A-846496 | Replacement orange electrode stack for the 10.6 eV ION Science MiniPID 2 sensor |
View image: Lamp 10.6eV
Lamp 10.6eV
|
LA4TM600 | Replacement 10.6 eV PID lamp for the Tiger XT |
View image: Mini PID 10.6eV 6-pin (orange)
Mini PID 10.6eV 6-pin (orange)
|
MP6SX66XU2 | Replacement PID sensor for the Tiger XTL |
View image: PTFE Filter Disc (x10)
PTFE Filter Disc (x10)
|
A-861632 | Probe inlet designed to accurately pinpoint and sample target gases |
View image: Tiger Range Filter Clamp O-Ring (x5)
Tiger Range Filter Clamp O-Ring (x5)
|
A-912363 | Replacement O-rings for sealing the Tiger XT range filter clamp |
View image: Tiger Range Probe (x5)
Tiger Range Probe (x5)
|
A-880214 | Replacement sampling probe designed to accurately pinpoint and sample target gases |
Tiger XTL is a cost-effective PID detector designed for routine ppm measurement of volatile organic compounds. Its focused functionality, straightforward operation and rugged construction make it suitable for industrial, environmental and workplace VOC monitoring applications.
Tiger XTL uses photoionisation detection (PID) technology to measure a wide range of volatile organic compounds (VOCs) at ppm concentrations.
Detection capability depends on factors including the compound’s ionisation energy, the PID lamp fitted and the expected concentration. Use the ION Science gas search tool or contact an authorised representative to confirm suitability for your application.
The Tiger XTL provides essential VOC detection functionality for customers who do not require features such as ppb sensitivity, data logging or health and safety operating modes. Other Tiger models are available for applications requiring these additional capabilities
No. Tiger XTL is configured for ppm VOC detection and does not provide ppb sensitivity.
If your application requires lower-level VOC detection, compare the other available Tiger models or contact ION Science for product-selection guidance.
The Tiger XTL is designed around a 10.6 eV PID lamp, which detects a broad range of VOCs. Customers should confirm that the target compound has an ionisation energy below the lamp energy before purchasing.
No. Tiger XTL has a fixed configuration focused on essential ppm VOC monitoring. Ppb sensitivity, data logging and Health and Safety Mode cannot be added to this model.
This focused configuration supports straightforward operation and cost-effective ownership for users who do not require these additional capabilities.
The Tiger XTL is supplied with ION Science’s standard warranty. Available 2 years extended-warranty when registered on the ION Science website within one month of purchase.
A fully charged Tiger XTL battery provides up to 24 hours of operation.
Actual battery life may vary depending on instrument use, battery condition, alarm activity and environmental conditions.
ION Science recommends factory servicing and calibration every 12 months.
Users should also implement a regular inspection, testing and maintenance programme between scheduled services, based on the application, operating environment and applicable workplace procedures.
Refer to the Tiger XTL user manual for detailed servicing and calibration guidance.
Inspect the filter regularly and replace it immediately if it appears contaminated, damaged or obstructed.
Replacement may typically be required after approximately 100 hours of use, although the appropriate interval will depend on the application, level of airborne contamination and operating environment.
Follow the inspection and replacement guidance within the Tiger XTL user manual.
Find your local distributor
Ready to purchase the Tiger XTL? Use our interactive map to locate an authorised ION Science distributor near you for product availability, expert advice and local support.
Have questions about the Tiger XTL?
Our experts are on hand to answer questions about the Tiger XTL, its capabilities and the best solution for your monitoring requirements.












