Cub 10.6 eV Wearable PID VOC Detector
Cub 10.6 eV is a compact, lightweight personal VOC gas detector designed to be worn comfortably within the breathing zone. If VOC exposure exceeds a pre-set alarm level, audible, vibration and flashing LED alarms immediately alert the wearer, with real-time readings clearly shown on the bright, backlit LCD display.
Cub is robust yet comfortable to wear, with a dynamic range of 1 ppb to 5000 ppm, capable of measuring over 480 selectable compounds. CubDoc docking stations are available for USB communication, charging and calibrating your instrument, dependent on your requirements.
- Responds in less than 13 seconds for rapid VOC detection
- Uses patented Fence Electrode Technology and an Anti-contamination Design to support reliable PID performance
- Logs up to 30,000 readings for exposure analysis and reporting
- Offers up to 12 hours of battery life for continuous personal VOC monitoring
ATEX_logo
Logo-IECEx-TM-500px
SGS logo_digital_80px
Leading Technology
Designed with Operators in Mind
Extended Warranty
| Specification | Details |
|---|---|
| Detectable Ranges | ppm: 0 to 5,000 ppm (0.1 ppm sensitivity) ² ³ ⁴ ppb: 0 to 5,000 ppm (0.001 ppm sensitivity) ² ³ ⁴ |
| Accuracy | +/- 5% displayed reading +/- one digit ² ³ |
| Response Time | T90 < 13 seconds ² |
| Alarms | Visual: Flashing Red and Amber LED Audible: 95 dB @ 300 mm |
| Data Logging | 30,000 data logs |
| Specification | Details |
|---|---|
| Battery | Li-ion battery |
| Operating Time | Up to 12 hours |
| Charging Time | Up to 4 hours |
| Specification | Details |
|---|---|
| Operating Temperature | -20ºC to +55ºC (-4 ºF to +131 ºF) |
| Ingress Protection Rating | IP65 ¹ |
| Weight | 111 g (3.9 oz) |
| Dimensions | 61 x 66 x 59 mm (2.4 x 2.6 x 2.3 in) |
| Specification | Details |
|---|---|
| ATEX | II 1 G Ex ia IIC T4 Ga Baseefa11ATEX0027 |
| IECEx | Ex ia IIC T4 Ga IECEx BAS 11.0014 |
| North American Hazardous Location Approvals | Class I, II and III, Division 1, Hazardous (Classified) Locations |
1 IP65 with PTFE filter fitted, IP64 without PTFE filter fitted.
2 Specifications are based on isobutylene calibrations at 20 °C and 1000mBar. All specifications quoted are at calibration point and under the same ambient conditions.
3 For indicative measurement only. Quoted accuracy achievable up to 2,000 ppm. For more accurate detection, calibration around concentration of interest is recommended.
4 Maximum reading is achieved with certain analytes.
- Cub 10.6 eV Brochure English
- Cub 10.6 eV Brochure Chinese
- Cub 10.6 eV Brochure French
- Cub 10.6 eV Brochure German
- Cub 10.6 eV Brochure Italian
- Cub 10.6 eV Brochure Spanish
- Cub User Manual English
- Cub User Manual Chinese
- Cub User Manual French
- Cub User Manual German
- Cub User Manual Italian
- Cub User Manual Spanish
- Cub PC Software V0.0.0.62
Cub 10.6 eV Personal VOC Gas Detector
How Photoionisation Detection (PID) Works
Accessories
| Item | Part number | Description |
|---|---|---|
View image: Cub Calibration Docking Station – Australian Plug
Cub Calibration Docking Station – Australian Plug
|
CDASXCSX-X | Calibration Dock to support and carry out quick and easy bump testing and calibration of the unit before use |
View image: Cub Calibration Docking Station – European Plug
Cub Calibration Docking Station – European Plug
|
CDASXCEX-X | Calibration Dock to support and carry out quick and easy bump testing and calibration of the unit before use. |
View image: Cub Calibration Docking Station – UK Plug
Cub Calibration Docking Station – UK Plug
|
CDASXCKX-X | Calibration Dock to support and carry out quick and easy bump testing and calibration of the unit before use. |
View image: Cub Calibration Docking Station – US Plug
Cub Calibration Docking Station – US Plug
|
CDASXCAX-X | Calibration Dock to support and carry out quick and easy bump testing and calibration of the unit before use. |
View image: PID Check Pen
PID Check Pen
|
4/QM-01 | Portable check pen for confirming the response of compatible PID instruments |
Spares
| Item | Part number | Description |
|---|---|---|
|
Cub PTFE and Seal Kit
|
A-871205 | Replacement PTFE components and seals for maintaining the Cub sample inlet. |
View image: Electrode Stack White
Electrode Stack White
|
A-846267 | Replacement white electrode stack for the PID sensor |
View image: Lamp 10.6eV
Lamp 10.6eV
|
LA4TM600 | Replacement 10.6 eV PID lamp for the Tiger XT |
View image: MiniPID 2 6-pin 10.6eV
MiniPID 2 6-pin 10.6eV
|
MP6SX6BXU2 | Replacement 6-pin MiniPID 2 sensor |
View image: PTFE Filter for Cub – pack of 10
PTFE Filter for Cub – pack of 10
|
A-871243 | Replacement PTFE filters for protecting the Cub sample inlet from particles |
View image: PTFE Filter for Cub – pack of 100
PTFE Filter for Cub – pack of 100
|
A-871244 | Replacement PTFE filters for protecting the Cub sample inlet from particles. |
The ION Science Cub is a wearable personal gas detector designed to monitor worker exposure to volatile organic compounds (VOCs). Using advanced PID (photoionisation detection) technology, it provides fast, accurate detection of hundreds of VOCs, helping protect personnel in industries such as oil and gas, chemicals, manufacturing, environmental monitoring and emergency response.
The ION Science Cub with a 10.6 eV lamp detects a wide range of volatile organic compounds (VOCs). It measures concentrations from low ppm levels up to 5,000 ppm and supports response factors for hundreds of different compounds, making it a versatile personal gas detector for VOC monitoring.
The ION Science Cub is the world's smallest and lightest wearable PID personal gas detector, offering rapid response, high sensitivity and reliable performance in challenging environments. Its humidity-resistant, anti-contamination sensor design helps deliver accurate readings with minimal maintenance, while audible, visual and vibrating alarms alert users when VOC levels exceed preset limits.
Yes. The ION Science Cub personal gas detector is certified for use in hazardous locations with ATEX and IECEx approvals. It is designed for workers operating in potentially explosive atmospheres where reliable VOC monitoring is essential for maintaining safety and regulatory compliance.
Yes. The ION Science Cub can be upgraded through ION Science PC software, allowing firmware updates as new functionality becomes available. For optimum performance, ION Science recommends annual factory servicing and calibration, alongside routine maintenance and regular bump testing as part of your site safety procedures.
Find an ION Science Distributor
Looking for the ION Science Cub? Our global network of authorised distributors can help you choose the right personal gas detector, provide expert advice and support you with purchasing, servicing and calibration. Find your nearest distributor today.
Need Help Choosing the Right Personal Gas Detector?
Whether you have a technical question, need advice on the ION Science Cub, or want help selecting the right personal gas detector for your application, our experts are here to help. Get in touch with the ION Science team today.