{"id":241746,"date":"2017-05-03T00:00:00","date_gmt":"2017-05-02T23:00:00","guid":{"rendered":"https:\/\/ionscience.com\/news\/continuous-benzene-specific-monitoring\/"},"modified":"2017-05-03T00:00:00","modified_gmt":"2017-05-02T23:00:00","slug":"continuous-benzene-specific-monitoring","status":"publish","type":"post","link":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/","title":{"rendered":"Continuous benzene specific monitoring using the Titan"},"content":{"rendered":"<h2>Continuous benzene specific monitoring<\/h2>\n<p>Benzene is a critical industrial chemical typically used within the petrochemical industry. However, it is one of the most toxic components and is a known human carcinogen.<\/p>\n<p>See our full list of Technical Application Articles within the <a href=\"https:\/\/ionscience.com\/gas-and-leak-detectors\/resource-centre\/\" target=\"_blank\" rel=\"noopener noreferrer\">resource centre<\/a>.<\/p>\n<h2>About the Titan<\/h2>\n<p>Set to change the game in refinery applications, Titan is the first truly selective fixed benzene monitor on the market.<\/p>\n<p>Titan is a fixed, continuous, real-time, benzene-specific monitor designed for petrochemical environments, providing the ultimate device for plant and worker safety.<\/p>\n<p>The instrument is wall-mounted with a dynamic detection range or\u00a00 \u2013 20 ppm with 0.1 ppm sensitivity to benzene. Titan samples gas from the environment once per minute and within just 60 seconds an accurate benzene measurement is displayed.<\/p>\n<p>Titan provides an immediate warning alarm system with two operator configurable levels, ensuring workers are kept safe and protected to the standards required on site. The instrument incorporates two relay outputs allowing you to install your own required alarm system.<\/p>\n<p>Titan\u2019s continuous, real-time measurement allows trends to be monitored over time, and communicated via 4-20 mA or RS485. Data is stored internally and can be downloaded remotely for analysis.<\/p>\n<p>Designed to be easily installed and serviced, the modular design allows the Ex d case to be installed well in advance of commissioning. The internal service module can be removed\u00a0and replaced as a remotely serviceable plug and play cartridge.<\/p>\n<p>Titan incorporates Ion Science patented photoionisation detection (PID) sensor technology with proven resistance to humidity and contamination, ensuring optimal performance, however challenging your environment.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Benzene is a critical industrial chemical typically used within the petrochemical industry. However, it is one of the most toxic components and is a known human carcinogen.<\/p>\n","protected":false},"author":6,"featured_media":237164,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[235],"tags":[78,47],"class_list":{"0":"post-241746","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-industry-application","8":"tag-benzene","9":"tag-titan-fixed-benzene-specific-detector"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Continuous benzene specific monitoring using the Titan - Ion Science UK<\/title>\n<meta name=\"description\" content=\"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Continuous benzene specific monitoring using the Titan - Ion Science UK\" \/>\n<meta property=\"og:description\" content=\"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\" \/>\n<meta property=\"og:site_name\" content=\"Ion Science UK\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-02T23:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ionscience.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Emily Lane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Emily Lane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\"},\"author\":{\"name\":\"Emily Lane\",\"@id\":\"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371\"},\"headline\":\"Continuous benzene specific monitoring using the Titan\",\"datePublished\":\"2017-05-02T23:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\"},\"wordCount\":263,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all\",\"keywords\":[\"Benzene\",\"Titan fixed benzene specific detector\"],\"articleSection\":[\"Industry &amp; Application\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\",\"url\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\",\"name\":\"Continuous benzene specific monitoring using the Titan - Ion Science UK\",\"isPartOf\":{\"@id\":\"https:\/\/ionscience.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all\",\"datePublished\":\"2017-05-02T23:00:00+00:00\",\"author\":{\"@id\":\"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371\"},\"description\":\"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.\",\"breadcrumb\":{\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage\",\"url\":\"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all\",\"contentUrl\":\"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all\",\"width\":800,\"height\":600,\"caption\":\"Titan, the benzene specific monitor\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ionscience.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Continuous benzene specific monitoring using the Titan\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ionscience.com\/en\/#website\",\"url\":\"https:\/\/ionscience.com\/en\/\",\"name\":\"Ion Science UK\",\"description\":\"Advanced gas detectors, PID\/VOC detectors, SF6 leak detectors, corrosion monitors, mercury vapour detectors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ionscience.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371\",\"name\":\"Emily Lane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g\",\"caption\":\"Emily Lane\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Continuous benzene specific monitoring using the Titan - Ion Science UK","description":"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/","og_locale":"en_GB","og_type":"article","og_title":"Continuous benzene specific monitoring using the Titan - Ion Science UK","og_description":"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.","og_url":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/","og_site_name":"Ion Science UK","article_published_time":"2017-05-02T23:00:00+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/ionscience.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg","type":"image\/jpeg"}],"author":"Emily Lane","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Emily Lane","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#article","isPartOf":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/"},"author":{"name":"Emily Lane","@id":"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371"},"headline":"Continuous benzene specific monitoring using the Titan","datePublished":"2017-05-02T23:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/"},"wordCount":263,"commentCount":0,"image":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all","keywords":["Benzene","Titan fixed benzene specific detector"],"articleSection":["Industry &amp; Application"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/","url":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/","name":"Continuous benzene specific monitoring using the Titan - Ion Science UK","isPartOf":{"@id":"https:\/\/ionscience.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage"},"image":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all","datePublished":"2017-05-02T23:00:00+00:00","author":{"@id":"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371"},"description":"Benzene monitoring is important because it is by far the most toxic component of many fuels, and it is a known human carcinogen.","breadcrumb":{"@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#primaryimage","url":"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all","contentUrl":"https:\/\/e7552ege7qf.exactdn.com\/wp-content\/uploads\/2021\/07\/titan_benzene_specific_monitor_c6h6-1.jpg?strip=all","width":800,"height":600,"caption":"Titan, the benzene specific monitor"},{"@type":"BreadcrumbList","@id":"https:\/\/ionscience.com\/en\/news\/continuous-benzene-specific-monitoring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ionscience.com\/en\/"},{"@type":"ListItem","position":2,"name":"Continuous benzene specific monitoring using the Titan"}]},{"@type":"WebSite","@id":"https:\/\/ionscience.com\/en\/#website","url":"https:\/\/ionscience.com\/en\/","name":"Ion Science UK","description":"Advanced gas detectors, PID\/VOC detectors, SF6 leak detectors, corrosion monitors, mercury vapour detectors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ionscience.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/ionscience.com\/en\/#\/schema\/person\/c84246b4c2dd4489e463aa374c1e5371","name":"Emily Lane","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9d0e3f17b128babe90c34c9970c69bc7f0568675cc08c509bb1a3c1a4d468b89?s=96&d=mm&r=g","caption":"Emily Lane"}}]}},"_links":{"self":[{"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/posts\/241746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/comments?post=241746"}],"version-history":[{"count":0,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/posts\/241746\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/media\/237164"}],"wp:attachment":[{"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/media?parent=241746"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/categories?post=241746"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ionscience.com\/en\/wp-json\/wp\/v2\/tags?post=241746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}