Tiger XT Portable PID VOC Detector
The ION Science Tiger XT is a portable PID VOC detector designed for rapid, accurate volatile organic compound (VOC) detection across demanding industrial and environmental applications.
Powered by advanced photoionisation detection (PID) technology, Tiger XT delivers reliable performance in challenging conditions.
- Rapid response and clear-down in less than two seconds
- Accurate ppm VOC measurement up to 20,000 ppm as standard
- Optional sensitivity down to 1 ppb for low-level VOC detection
- Reliable performance in humid and contaminated conditions
- Intrinsically safe for use in hazardous environments
- Flexible, upgradeable functionality
- Designed for a low total cost of ownership
ATEX_logo
Logo-IECEx-TM-500px
SGS logo_digital_80px
Robust Design
Large Internal Gas Table
Leading Warranty
*5 years instrument warranty when registered on the ION Science website within one month of purchase. Please refer to the ION Science Warranty Statement for full terms and conditions.
| Specification | Details |
|---|---|
| Range** | 10.6 eV: 1 ppb - 20,000 ppm*** 11.7 eV: 9,000 ppm***# |
| Minimum Resolution | 10.6 eV: 0.001 ppm (1 ppb)*** 11.7 eV: 0.6 ppm (600 ppb)*** |
| Accuracy | 10.6 eV: +/- 5% display reading or +/- one-digit *** 11.7 eV: +/- 12% display reading *** |
| Response Time | 10.6 eV: T90 < 2 seconds 11.7 eV: < 6 seconds |
| Flow Rate | ≥ 220 mL/min |
| Alarms | Flashing LEDs amber (low alarm) red (high alarm) Sounder 95 dBA at 300 mm (12”) Vibration on alarm |
| Alarm Conditions | Pre-programmed TWA and STEL* |
| Operation | 6-button operation |
| Specification | Details |
|---|---|
| Battery | Li-ion battery |
| Operating Time | Up to 24 hours |
| Charging Time | Up to 8 hours |
| Specification | Details |
|---|---|
| Operating Temperature | 10.6 eV: -20 °C to +60 °C (-4 ºF to +140 ºF) 11.7 eV: 0 °C to +60 °C (+32 ºF to + 140 ºF) |
| Humidity | 0 - 99% Relative Humidity (non-condensing) |
| Ingress Protection Rating | IP65 |
| Weight | 870 g (1.9 lb) |
| Dimensions (with probe) | 91 x 370 x 60 mm ( 3.5 x 14.5 x 2.3 in) |
| Specification | Details |
|---|---|
| ATEX | II 1G Ex ia IIC T4 Ga SGS25ATEX0002X, SGS25ATEX0003X, SGS25ATEX0004X |
| IECEx | IECEx SGS 25.0002X |
| EMC | EN61326-1:2013, EN50270:2015 & CFR 47:2008 Class A |
| North American Hazardous Location | Class 1 Division 1, Groups A, B, C & D, T4 SGSNA/25/CA/00001X |
- Tiger XT Brochure English
- Tiger XT Brochure Chinese
- Tiger XT Brochure French
- Tiger XT Brochure German
- Tiger XT Brochure Italian
- Tiger XT Brochure Spanish
- Tiger XT User Manual English
- Tiger XT User Manual Chinese
- Tiger XT User Manual French
- Tiger XT User Manual German
- Tiger XT User Manual Italian
- Tiger XT User Manual Spanish
- Tiger PC Software V1.0.2.23
Tiger XT Handheld VOC Gas Detector – Product Overview
Unboxing the Tiger XT VOC Gas Detector
The Tiger XT Range of Handheld VOC Gas Detectors
How Photoionisation Detection (PID) Works
Accessories
| Item | Part number | Description |
|---|---|---|
View image: Car Charger Lead
Car Charger Lead
|
1/jawu-01 | Vehicle charging lead for powering or charging the Tiger XT while travelling |
View image: Multi Adaptor with Pipe Connector
Multi Adaptor with Pipe Connector
|
A-912338 | This adaptor features a quick-release connector for attaching longer lengths of tubing with a 4 mm internal diameter and 6 mm external diameter |
View image: Multi Adaptor with Probe Extension 1000mm
Multi Adaptor with Probe Extension 1000mm
|
A-912337 | Flexible 1000mm probe extension for sampling hard to reach areas with the Tiger XT and Tiger XTL |
View image: Multi Adaptor with Probe Extension 300mm
Multi Adaptor with Probe Extension 300mm
|
A-912336 | Flexible probe attaches to the Tiger XT range and is used for hard to reach spaces. |
View image: Tiger XT Container Probe
Tiger XT Container Probe
|
A-912339 | Designed for reliable remote sampling in demanding applications |
View image: Tiger XT Fire Investigation Kit
Tiger XT Fire Investigation Kit
|
TXXXSRBMP-0000 | A complete accessory kit for the Tiger XT, supplied with a premium carrying case, rechargeable battery pack, charger assembly, multi-region mains adaptor, car charger lead, PID response check pen, 1m flexi probe, pack of 10 PTFE filters, exhaust barb and USB cable. |
View image: Tiger XT Range Accessory Kit
Tiger XT Range Accessory Kit
|
A-912300 | Contains a PTFE filter discs, sensor O-ring seal, carbon filter, lamp cleaning compound, cal adaptor, PID stack removal tool, lanyard, and battery lid catch for quick, simple maintenance. |
Spares
| Item | Part number | Description |
|---|---|---|
View image: Electrode Stack White
Electrode Stack White
|
A-846267 | Replacement white electrode stack for the PID sensor |
View image: Lamp 10.6eV
Lamp 10.6eV
|
LA4TM600 | Replacement 10.6 eV PID lamp for the Tiger XT |
View image: MiniPID 2 6-pin 10.6eV
MiniPID 2 6-pin 10.6eV
|
MP6SX6BXU2 | Replacement 6-pin MiniPID 2 sensor |
View image: PTFE Filter Disc (x10)
PTFE Filter Disc (x10)
|
A-861632 | Probe inlet designed to accurately pinpoint and sample target gases |
View image: Tiger Range Filter Clamp O-Ring (x5)
Tiger Range Filter Clamp O-Ring (x5)
|
A-912363 | Replacement O-rings for sealing the Tiger XT range filter clamp |
View image: Tiger Range Probe (x5)
Tiger Range Probe (x5)
|
A-880214 | Replacement sampling probe designed to accurately pinpoint and sample target gases |
Tiger XT uses photoionisation detection technology to measure a wide range of volatile organic compounds.
Whether a particular compound can be detected depends on factors including its ionisation energy, the PID lamp fitted and the required measurement range.
Use the ION Science gas search tool or contact an authorised representative to confirm whether Tiger XT is suitable for a particular gas or application.
Tiger XT provides ppm VOC measurement as standard, across a wide range extending up to 20,000 ppm.
Optional ppb sensitivity can be enabled for applications requiring low-level VOC measurements down to 1 part per billion.
Yes. Optional ppb sensitivity extends the Tiger XT measurement capability down to 1 part per billion.
Contact ION Science or your local authorised representative to confirm the appropriate Tiger XT configuration for your application.
Tiger XT has a response and clear-down time of less than two seconds, helping users identify changing VOC concentrations and potential emission sources rapidly.
Actual performance may depend on factors including the compound being measured, instrument configuration and operating conditions.
Yes. Tiger XT is intrinsically safe and meets ATEX, IECEx and relevant North American and Canadian Standards.
Check the certification shown on the instrument and within its technical documentation to confirm suitability for the intended location and application.
Yes. Eligible Tiger XT functionality can be enabled remotely using TigerPC software, allowing the instrument to adapt as your monitoring requirements change.
Available upgrades include ppb sensitivity, Health and Safety Mode and a selection of data-logging functions. Availability may depend on the instrument’s existing configuration.
Refer to the Tiger XT user manual or contact your local authorised ION Science representative for guidance.
ION Science recommends factory servicing and calibration every 12 months.
Users should also implement a regular inspection, testing and maintenance programme between scheduled services, based on the application, operating environment and applicable workplace procedures.
Refer to the Tiger XT user manual for detailed maintenance and calibration guidance. Or contact your local authorised ION Science representative.
Tiger XT servicing and calibration are available through ION Science and selected authorised representatives and service centres.
Use the Where to Buy map to find an appropriate service provider in your region, or contact ION Science for assistance.
Tiger XT connects to TigerPC software, which supports instrument configuration and access to eligible upgrades and data-management functionality.
Refer to the Tiger XT user manual and TigerPC guidance for compatibility and connection instructions.
* Dependent on model and gas
** Maximum reading is obtained with some analytes such as ethanol
*** Specifications are based on calibration of isobutylene at 20 ° C and 1000 mBar. All specifications shown are at the calibration point and under the same environmental conditions.
**** Based on continuous operation.
# For indicative measurements only. Quoted accuracy achievable up to 2,000 ppm. For more accurate detection, calibration around the concentration of interest is recommended.
Find Your Local Tiger XT Distributor
Ready to purchase a Tiger XT portable VOC detector?
Use our interactive map to find an authorised ION Science representative in your region. Local representatives can provide product availability, application guidance, quotations and ongoing support.
Find the Right Tiger XT for Your Application
From confirming gas compatibility and measurement requirements to selecting the appropriate functionality and accessories, our team can help you configure Tiger XT for your application.
Tell us what you need to detect, the expected concentration range and where the instrument will be used. We will help you identify the appropriate next step.












