Panther Portable Gas Leak Detector
Panther is a portable gas leak detector designed to rapidly locate and quantify leaks from systems containing hydrogen, helium and refrigerants. Using thermal conductivity detection technology, this handheld gas leak detector delivers reliable measurements across demanding industrial applications.
Panther is available in standard and PRO configurations. The standard model provides the core gas selection, leak location and measurement functionality. Panther PRO adds data logging and Bluetooth connectivity, enabling users to record up to 10 days of continuous data and export results through compatible ION PC software.
- One-second T90 response for rapid leak detection
- Multiple measurement units for accurate gas leak rate measurement
- Stable sample flow in draughty environments
- Flexible probe, colour display and one-handed operation
- Audible, vibration and visual leak alarms
Long Rechargeable Battery Life
Unwavering Performance
Exceptional Sensitivity
| Specification | Details |
|---|---|
| Response Time | T90 < 1 second |
| Flow Rate | 2 cc/min |
| Measurement Units | mL/s, cc/s, g/yr, mg/m3, ppm, % vol |
| Alarms | Audible ≥ 90 dBa at 10 cm Visual flashing LEDs (low & high alarms) |
| Operation | 8-button operation |
| Specification | Details |
|---|---|
| Battery | Rechargeable Li-ion battery |
| Battery Life | Up to 20 hours |
| Specification | Details |
|---|---|
| Operating Temperature | 0 °C to +50 °C (+32 ºF to +122 ºF) |
| Humidity | 0- 99% Relative Humidity (non-condensing) |
| Ingress Protection Rating | IP44 |
| Weight | 447 g (1 lb) |
| Dimensions | 320 x 80 x 55 mm (12.5 x 3.1 x 2.2 in) |
- Panther Brochure English
- Panther Brochure Chinese
- Panther Brochure French
- Panther Brochure German
- Panther Brochure Italian
- Panther Brochure Spanish
- Panther User Manual English
- Panther User Manual Chinese
- Panther User Manual French
- Panther User Manual German
- Panther User Manual Italian
- Panther User Manual Spanish
- ION PC Software V1.0.175
- Panther Firmware V1.65
The Panther Gas Leak Detector From ION Science
How to Use The Panther Gas Leak Detector From ION Science
How Thermal Conductivity Works
Is the Panther Gas Leak Detector Cost-Effective?
Accessories
| Item | Part number | Description |
|---|---|---|
View image: Cable USB A male to USB C male 1m black with ferrite
Cable USB A male to USB C male 1m black with ferrite
|
1/VC-27 | One-metre USB-A to USB-C cable for charging and data connection |
View image: Cable USB A male to USB C male 2m black with ferrites
Cable USB A male to USB C male 2m black with ferrites
|
1/VC-29 | Two-metre USB-A to USB-C cable for charging and data connection |
View image: Panther CalCheck 5% Hydrogen / 95% Nitrogen
Panther CalCheck 5% Hydrogen / 95% Nitrogen
|
A-907308 | Portable reference source for checking Panther response to a 5% hydrogen and 95% nitrogen gas mixture |
View image: Panther CalCheck Helium
Panther CalCheck Helium
|
A-907306 | Portable helium reference source for checking Panther detector response |
View image: Panther CalCheck SF6
Panther CalCheck SF6
|
A-907307 | Portable SF6 reference source for checking Panther detector response |
View image: Power Supply 5VDC 1.20A 6W USB – Multi-Head
Power Supply 5VDC 1.20A 6W USB – Multi-Head
|
1/VS-32 | Multi-head 5 V USB power supply for charging the Panther instrument |
Spares
| Item | Part number | Description |
|---|---|---|
|
Panther Capillary Probe – short (for 200mm Flexible Probe)
|
A-907229 | Replacement sampling probe for Panther |
|
Panther Capillary Probe – Standard
|
A-907228 | Replacement sampling probe for the Panther |
View image: Panther Flexible Probe 200mm
Panther Flexible Probe 200mm
|
A-907227 | Replacement sampling probe for the Panther |
View image: Panther Flexible Probe Body Assembly
Panther Flexible Probe Body Assembly
|
A-907298 | Replacement body assembly for the Panther flexible probe |
|
Panther Nozzle
|
907209-RWK | Replacement sampling nozzle for the Panther gas leak detector |
|
Panther Probe Sleeve (pack of 5)
|
A-907289 | Replacement sleeves for protecting the Panther probe during use |
Yes. Panther is suitable for detecting leaks from pressurised hydrogen systems and has a specified hydrogen sensitivity of 3.8 × 10⁻⁶ cc/s, compared with 5 × 10⁻⁶ cc/s for helium.
Panther has demonstrated relative immunity to high electromagnetic fields. The ION Science R&D Team conducted several tests at the UK’s National Physics Laboratory, a report is available upon request.
The internal piezo pump provides extremely stable and constant flow rates, even when used in draughty environments.
No. In addition to leak rate calibration, it’s also calibrated to a ‘span’ concentration.
Both models provide rapid leak location and measurement. Panther PRO additionally includes data logging and Bluetooth connectivity, allowing recorded results to be transferred to compatible ION PC software.
The standard Panther is suited to applications where users need to locate and quantify leaks without storing inspection data.
Yes. Panther PRO provides approximately 10 days of continuous data logging. Recorded sessions can be downloaded using compatible ION PC software to support analysis and reporting.
Panther detects gases whose thermal conductivity differs from the surrounding atmosphere, including hydrogen, helium and a range of refrigerants. Customers should consult the current Panther gas table or contact their local ION Science representative to confirm suitability for a particular gas and background atmosphere.
Panther draws a sample through its probe using an internal piezo pump. Its micro thermal conductivity detector measures changes in thermal conductivity between the sample and the surrounding air, providing a rapid indication when a detectable gas is present.
No. Panther does not chemically identify an unknown gas. The expected gas must be selected from the internal gas table so that the instrument can apply the appropriate response and display an accurate measurement.
Yes. Panther can be used to trace and pinpoint a leak before quantifying its rate or concentration. Move the probe slowly across the inspection area, retrace the route when a leak is indicated, and hold the probe over the source until the reading stabilises.
Panther has a T90 response time of one second under the specified test conditions. This rapid response helps users efficiently inspect pipework, joints, valves, seals and other potential leak points.
Panther supports six selectable measurement units:
- ml/s
- cc/s
- g/year
- ppm
- mg/m³
- % volume
The appropriate unit will depend on whether the application requires a leak-rate or concentration measurement.
Yes. Panther can detect a range of refrigerants included within its internal gas table. Customers should confirm that the particular refrigerant used in their system is supported before selecting the instrument.
Find your nearest distributor
Find an authorised ION Science distributor in your region to purchase Panther and access expert support for your gas leak detector requirements.
Need a gas leak detector?
Our experts are here to answer your questions about leak detection, product capabilities and selecting the right instrument for your application.