Titan 2 Selective Fixed Benzene Monitor
Titan 2 is a selective fixed benzene monitor designed for continuous, benzene-specific measurement in industrial environments.
- Measures benzene from 0.02 to 20 ppm, with a 20 ppb lower detection limit and 10 ppb resolution
- Produces a new benzene measurement every minute for continuous monitoring
- Features an interchangeable service module and internal heating to simplify maintenance and support stable operation across changing temperatures
- Onboard storage for a minimum of six months of measurement data
- Integrates with site control and alarm systems through 4–20 mA, RS485 Modbus and two configurable relay outputs
ATEX_logo
Logo-IECEx-TM-500px
QPS-C-C-255
Ultra-Low Benzene Detection
Built for Hazardous Areas
Low Maintenance, High Reliability
| Specification | Details |
|---|---|
| Sensitivity | Benzene-specific within typical petrochemical matrix |
| Detectable Range | 0.02 ppm - 20 ppm |
| Measuring Frequency | 60 seconds |
| Lower Level of Detection | 0.02 ppm (20 ppb) (10 ppb resolution) |
| Accuracy | ± 50 ppb or ± 10% (whichever is greater*) |
| Flow Rate | Sample flow rate ≥ 100 mL/min |
| Display | Graphic BW LCD 64 x 128 pixels with backlight Bright LEDs for normal operation, fault and alarm Two magnetic switches for menu operation |
| Specification | Details |
|---|---|
| Cable Entry | Two ¾ NPT gland threads |
| Power Requirements | Vin (nom) 24 V DC @ 3.2 A (recommended) Vin (max) 32 V DC @ 2.4 A Vin (min) 19 V DC @ 4.0 A |
| Relay Output | Two isolated outputs, voltage free, 24 v DC @ 1.25 A |
| Communication | Isolated 4-20 mA output Isolated RS 485 Modbus connection via ASCII or RTU (simplex/half duplex or fully duplex) Micro USB (PC Software) |
| Specification | Details |
|---|---|
| Operating Temperature | -20ºC to +50ºC (-4 ºF to +122 ºF) |
| Temperature Stability | Internally heated |
| Humidity | 0 to 99% Relative Humidity (non-condensing) |
| Ingress Protection Rating | IP65 |
| Weight | 15 kg (33 lbs) |
| Dimensions | 219 x 219 x 172 mm (8.6 x 8.6 x 6.8 in) |
| Specification | Details |
|---|---|
| ATEX | Ex II 2G Ex db IIB+H₂ T4 Gb FTZU 14 ATEX 0172X |
| IECEx | Ex db IIB+H₂ T4 Gb IECEx FTZU 14.0030X |
| North American Hazardous Location | Class I, AEx db IIB+H₂ T4 Gb / Ex db IIB+H₂ T4 Gb QPS LR1621-1 |
*± 10 ppb for readings ≤ 0.1 ppm
- Titan 2 Brochure English
- Titan 2 Brochure Chinese
- Titan 2 Brochure French
- Titan 2 Brochure German
- Titan 2 Brochure Italian
- Titan 2 Brochure Spanish
- Titan 2 User Manual English
- Titan 2 User Manual Chinese
- Titan 2 User Manual French
- Titan 2 User Manual German
- Titan 2 User Manual Italian
- Titan 2 User Manual Spanish
- Titan 2 PC Software V2.0.04
How Does Titan 2 Work?
Titan 2 Service Module
Titan 2 Product Overview
Accessories
| Item | Part number | Description |
|---|---|---|
|
Titan Case Service Module
|
875405 | Protective case for the service module for the Titan 2 |
Spares
| Item | Part number | Description |
|---|---|---|
View image: Hydrophobic Filter
Hydrophobic Filter
|
A-875417 | Replacement hydrophobic filter that helps prevent moisture entering the Titan 2 sample path |
|
Joint rapid fit 8/6 tube 1/4BSPP
|
5/JRC-01 | Rapid-fit tube connector for the Titan 2 sample system |
|
Titan Actuation Magnet Assembly
|
A-875265 | Replacement actuation magnet assembly for operating the Titan 2 enclosure controls |
|
Titan Enclosure Lid O-Ring
|
875404 | Replacement O-ring for maintaining the seal around the Titan 2 enclosure lid |
Titan 2 is a fixed benzene monitor designed for continuous, selective measurement in industrial environments. It can support occupational exposure monitoring, process safety, leak detection and the assessment of purification or vapour recovery systems.
Typical applications include oil and gas facilities, refineries, bulk storage terminals, chemical manufacturing and asphalt production.
Titan 2 provides:
- Isolated 4–20 mA output
- Isolated RS485 Modbus using ASCII or RTU
- Two isolated, voltage-free relay outputs
- Micro-USB connectivity for compatible PC software
These outputs enable integration with compatible site control, alarm and data-management systems.
Titan 2 produces a new benzene measurement every 60 seconds, providing a continuous sequence of readings for site monitoring and analysis.
Titan 2 measures benzene concentrations from 0.02 to 20 ppm. Its lower detection limit is 0.02 ppm, equivalent to 20 ppb, with a resolution of 10 ppb.
Titan 2 uses internally regulated heating to support stable operation across changing temperatures. ION Science recommends an operating range of −20°C to +50°C for optimum performance.
Customers should review the full environmental specification when planning an installation.
Get Titan 2 from an authorised ION Science partner
Looking to purchase a reliable benzene detector? Our worldwide distributor network provides local expertise, product availability and support to help you find the right solution for your gas detection requirements.
Speak to our benzene detection specialists
From workplace exposure monitoring to hazardous area applications, our team can help you understand how Titan 2 supports accurate benzene measurement and advise on the best solution for your needs.