TVOC 2 is a fixed continuous VOC detector designed to monitor volatile organic compounds in industrial environments. Using PID technology, this industrial VOC monitor provides real-time readings, helping facilities identify rising VOC concentrations and manage gas risks.
- Offers three selectable measurement ranges: 0–10 ppm, 0–100 ppm and 0–1,000 ppm
- Features a large LCD for clear local readings
- Provides a 4–20 mA output for integration with DCS and compatible control systems
- Uses a patented sensor design to help resist humidity and contamination
- Supports diffusive sampling as standard, with an adaptor available for externally pumped sampling
- ATEX and IECEx approved for use in Zone 1 and Zone 2 hazardous areas
ATEX_logo
Logo-IECEx-TM-500px
Reliable Performance
Built with Operators in Mind
Ultimate Flexibility
| Specification | Details |
|---|---|
| Range | 0 - 10 ppm, 0 - 100 ppm, 0 - 1000 ppm (user configurable) |
| Accuracy | 0 - 100 ppm ± 5% 100 - 1000 ppm ± 10% |
| Response Time | T90 < 35 seconds |
| Sampling method | Diffused |
| Display | 7 segment, 4 digit LCD, 4 colour LEDs |
| Alarms | 4-20 mA – selectable 2 mA and 3.5 mA options |
| Specification | Details |
|---|---|
| Power | 5-28 VDC, max 130 mA |
| Outputs | 4 - 20 mA requires an 8 - 35 VDC power supply For IS requirements 8-30 VDC power supply |
| Specification | Details |
|---|---|
| Operating Temperature | -20 ºC to + 50ºC (–4 ºF to +122 ºF) |
| Humidity | 0 - 95% Relative Humidity (non-condensing) |
| Ingress Protection | Instrument: IP65 Sensor: IP64 |
| Weight | 1.4 kg (3.1 lb) |
| Dimensions | 188 x 126 x 78 mm (7.4 x 4.9 x 3") |
| Specification | Details |
|---|---|
| ATEX | II 2G Ex ia IIC T4 Gb |
| IECEx | BAS 06.0057X |
| Baseefa | 05ATEX0277X |
- TVOC 2 Brochure English
- TVOC 2 Brochure Chinese
- TVOC 2 Brochure French
- TVOC 2 Brochure German
- TVOC 2 Brochure Italian
- TVOC 2 Brochure Spanish
- TVOC 2 User Manual English
- TVOC 2 User Manual Chinese
- TVOC 2 User Manual French
- TVOC 2 User Manual German
- TVOC 2 User Manual Italian
- TVOC 2 User Manual Spanish
TVOC 2 Fixed VOC Detector Product Overview
Accessories
| Item | Part number | Description |
|---|---|---|
|
TVOC 2 Flow Adaptor Cap Assembly
|
A-900218 | Flow adaptor cap assembly for connecting sample tubing to the TVOC 2 |
|
TVOC and TVOC 2 Tool Kit
|
A-849214 | Tool kit for routine maintenance of TVOC and TVOC 2 instruments |
Spares
| Item | Part number | Description |
|---|---|---|
View image: 10.6eV Lamp
10.6eV Lamp
|
LA4SFL3.2 | Replacement 10.6 eV PID lamp |
View image: Electrode Stack Orange
Electrode Stack Orange
|
A-846496 | Replacement orange electrode stack for the 10.6 eV ION Science MiniPID 2 sensor |
View image: MiniPID2 10.6eV 6-Pin (orange) TVOC 2
MiniPID2 10.6eV 6-Pin (orange) TVOC 2
|
MP6SDL6XU2 | Replacement PID sensor for the TVOC 2 |
|
Quick Blow Fuse (125mA)
|
68-0024 | Replacement 125 mA quick-blow fuse for the TVOC 2 |
|
TVOC 2 Seal Disk complete with O-Rings
|
A-900221 | Replacement TVOC 2 seal disc supplied complete with O-rings to maintain the enclosure seal |
View image: TVOC Calibration Magnet
TVOC Calibration Magnet
|
A-849219 | Calibration magnet used to access calibration functions on TVOC instruments |
A fixed continuous VOC detector is permanently installed at a defined location to monitor volatile organic compounds over time. Unlike a portable detector, it remains at the selected monitoring point and can provide measurements to a local display or compatible control equipment.
TVOC 2 combines continuous fixed-point monitoring with a large LCD and 4–20 mA output, providing both local visibility and integration with wider industrial monitoring arrangements.
TVOC 2 uses photoionisation detection technology to measure volatile organic compounds in the surrounding atmosphere. Its PID sensor responds to detectable VOCs and displays the measured concentration on the instrument’s LCD.
TVOC 2 provides a total VOC reading rather than identifying or distinguishing individual compounds. Its response depends on the VOCs present, their ionisation energies and the instrument configuration.
TVOC 2 offers three user-selectable measurement ranges:
- 0–10 ppm
- 0–100 ppm
- 0–1,000 ppm
The appropriate range should be selected according to the expected VOC concentrations and requirements of the application. ION Science or an authorised local representative can provide application guidance.
TVOC 2 uses diffusive sampling as standard, monitoring VOC concentrations at the detector’s installed location.
Where an application requires a sample to be drawn to the detector, TVOC 2 can be fitted with an adaptor and connected to a compatible external pump. The instrument does not contain an integrated sampling pump.
TVOC 2 is designed for fixed VOC monitoring in industrial locations such as:
- Manufacturing and production facilities
- Chemical processing plants
- Solvent handling and storage areas
- Industrial processing locations
- Plant rooms and production areas
- Hazardous-area installations
Its fixed installation makes it suitable for monitoring selected locations where VOC concentrations need to be measured continuously.
Yes. TVOC 2 provides a 4–20 mA analogue output that allows VOC measurements to be transmitted to a Distributed Control System or other compatible control equipment.
This enables facilities to incorporate VOC readings into existing monitoring and control arrangements. Compatibility and configuration requirements should be confirmed during installation planning.
TVOC 2 is ATEX and IECEx approved and can be installed in Zone 1 and Zone 2 hazardous areas, subject to the relevant certification and installation requirements.
Zone 1 installations require the power supply to be provided through an approved isolation barrier rated for the application. Users should refer to the current product manual and certification before installation.
TVOC 2 is designed to simplify routine maintenance. Its diffusive sampling method helps reduce contamination compared with pumped systems, which can reduce the need for regular PID lamp cleaning.
The PID sensor can be replaced quickly when servicing is required. An optional pipe connection cap is also available for applications where remote sampling is required.
Find an Authorised TVOC 2 Distributor
TVOC 2 is available through ION Science’s global network of authorised distributors. Our local representatives can provide guidance on measurement ranges, sampling arrangements, hazardous-area requirements and integration with compatible control equipment.
Need Help Choosing a Fixed Continuous VOC Detector?
Our gas detection specialists and authorised local representatives can help determine whether TVOC 2 is suitable for your application. Speak to us about expected VOC concentrations, measurement ranges, sampling requirements, hazardous-area installation or DCS integration.