Falco Diffused Gas Detector
Fixed VOC Gas Detector
The Falco fixed VOC Gas Detector, diffused model, is a fixed VOC gas detector that eliminates false readings found with other competing fixed detectors and continuously detects Volatile Organic Compounds (VOCs) in hazardous areas. The fixed VOC gas detector instrument is ideal for detecting VOCs in areas such as refineries and petrol chemical facilities.
Fixed VOC Gas Detector – Features
The Falco Diffused, fixed VOC gas detector has an externally located Intrinsically Safe sensor for quick and easy servicing without the need for a hot work permit. Dual certification allows your fixed VOC gas detector to be serviced and calibrated in a hazardous environment without having to remove power!
The standard Falco, both the Pumped and Diffused models are supplied with a 10.6 eV lamp allowing the fixed instrument to detect a wide range of VOC gases. The fixed gas detector has 4 detection ranges available, these ranges include 0 – 10 ppm, 0 – 50 ppm, 0 – 1000 ppm and 0 – 3000 ppm.
The fixed Falco TAC, both pumped TAC and diffused TAC models, utilise a 10.0 eV lamp to detect Total Aromatic Compounds (TACs) which help focus on benzene. The fixed Falco TAC is available with a detection range of 0 – 50 ppm.
Ultimate Performance
- The only fixed VOC detector specifically designed for extreme weather
- Typhoon technology stops condensation forming with the PID
- Cutting-edge sensor performance minimises drift & downtime
Ultimate Safety
- Eliminates false readings found with competing PID technology
- Multi-coloured status display can be seen from 20 metres in sunlight
- Fitted with long-life lamp for one year continuous use
- Ex d approved
Ultimate Flexibility
- Pumped and diffused fixed models available
- Diffused unit idea for detecting VOCs and TACs in areas such as refineries and petrol chemical facilities
- Falco fixed detector can be mounted virtually everywhere
- Four detection ranges available
- Selectable response factor for varying VOC selection
Technical Specification
Specification | Value |
---|---|
Sensor | Photoionisation detector |
Detection ranges and sensitivity with 10.6 eV lamp fitted* | 10.0 ppm, 0.001 ppm 50.0 ppm, 0.01 ppm 1000 ppm, 0.1 ppm 3000 ppm, 1 ppm |
Detection ranges and sensitivity with 10.0 eV lamp fitted* | 50.0 ppm, 0.01 ppm |
Response Time (T90) | Diffused models: <30 seconds** |
Accuracy | ± 5 % or ± 1 digit |
User Interface | OLED high contrast white on black: 128 x 64 pixels Screen size: 35 mm (w) x 17.5 mm (h) 5 magnetic switches with LED confirmation (up, down, left, right and enter) |
Status indicator | Bright visible status indicator: RED, AMBER, GREEN |
Output | 4 – 20 mA 2 programmable relays RS 485 Modbus |
Falco diffused environmental specification | Operational Temperature: – 40 to 50 °C 0-100 % RH and condensing humidity Storage temperature: – 40 to 60°C |
Ingress Protection | Main Unit:IP65 Sensor Head: IP65 |
Power | Working voltage: 12 to 40 Vdc Typical 2 W, Max 7 watts |
Mechanical Interface | 2 x cable entry points with 3/4″ NPT threads (left and right) |
Mounting Points | 2 x M8 |
Weight and Dimensions | 2.9 kg 205 (h) x 191 (w) x 125 (d) mm |
EMC | EMC Directive 2014/30/EU |
Certification | II 2G db ib IIC T4 Gb Class 1, Div 1 Groups ABCD T4 ISO9001:2015 |
* All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on isobutylene calibration at 20 °C and 1000 mBar.
** When set to continuous measurement
Modbus® is a registered trademark of Schneider Electric
What our customers say
View Case StudyView All Case StudiesView All Testimonials”“When assessing the potential hazards involved in our day-to-day operations it became evident that ION Science’s Falco fixed PID was the perfect solution for our application. We were particularly impressed with the instrument’s patented humidity resistant fence electrode technology and ability to work continuously in condensing atmospheres.”
Manager of Regulatory Affairs and QualityMonument Chemical
What our customers say
View Case StudyView All Case StudiesView All Testimonials”“In Italy, a new legislation with specific odour limit thresholds has also been recently introduced making it ever more important for companies that have treatment in their processes to monitor and improve the treatment efficiency of their systems in line with regulatory requirements.
Roberto PiscontiTechnologia and Ambiente
ION Science and its products are well known across our business so we were confident in the Falco’s ability to reliably and accurately measure VOCs in both inlet and outlet gas streams.”
Video Library
Downloads
For further supporting documentation for Falco Diffused, fixed VOC gas detector please see below.
Falco Diffused, Fixed VOC Gas Detector – Accessories and Replacement Parts
There are a number of accessories and replacement parts available for the Falco fixed voc gas detector, which can be found below. Please contact us if you would like more information or to place an order.
FAQs
If you have any further questions, please inquire now.
Global Distributors
All ION Science distributors are trained to the highest standards to provide you with access to our product portfolio locally, along with the best possible service and support. Find your local representative.
Falco Diffused, Fixed VOC Gas Detector Inquiry Form
Please complete the form below and a member of our team will contact you shortly.