Gas Detector Replacement Parts
Please select your ION Science Gas Detector or Leak Detector from the drop down list to view all available replacement parts for your instrument.
Home » Gas and Leak Detectors » Customer Support » Replacement Parts
Please select your ION Science Gas Detector or Leak Detector from the drop down list to view all available replacement parts for your instrument.
Register your instrument now to extend your warranty to up to five years!
Offers up to 24 hours of continuous use.
Contact us to place an order quoting the below part number.
Protects the PID from damage caused by general use.
Contact us to place an order quoting the below part number.
Protects the PID from damage caused by general use.
Contact us to place an order quoting the below part number.
The 10.6 eV lamp is an internal element to the ION Science PID sensor and is specifically designed for use only with ION Science PID sensors.
Contact us to place an order quoting the below part number.
The 10.6 eV lamp is an internal element to the ION Science PID sensor and is specifically designed for use only with ION Science PID sensors.
Contact us to place an order quoting the below part number.
Blue Electrode Stack for MiniPID 2 PPM Sensor.
Contact us to place an order quoting the below part number.
Red Electrode Stack for High Sensitivity MiniPID 2.
Contact us to place an order quoting the below part number.
Calibration Cap is used for ARA bump test and calibration.
Contact us to place an order quoting the below part number.
Filters for the probe.
Contact us to place an order quoting the below part number.
Used for the 300mm probe extension.
Contact us to place an order quoting the below part number.
Hand sensor to detect SF6.
Contact us to place an order quoting the below part number.
Long cap with stainless steel tip, PTFE in-liner.
Contact us to place an order quoting the below part number.
The smart sensor is pre-calibrated, certificate available on request.
Contact us to place an order quoting the below part number.
Used to connect the instrument with the computer.
Contact us to place an order quoting the below part number.
Used to charge MVI. EU, UK, AUS and US power sockets included.
Contact us to place an order quoting the below part number.
Protects the MVI from ingress of dirt and water.
Contact us to place an order quoting the below part number.
Protects the MVI from ingress of dirt and water.
Contact us to place an order quoting the below part number.
Protects the MVI from ingress of dirt and water.
Contact us to place an order quoting the below part number.
Protects the inner probe from damage.
Contact us to place an order quoting the below part number.
Accepts 4 x AA size batteries and connects to the instrument via a clip.
Contact us to place an order quoting the below part number.
Sensor for GasClam 2.
Contact us to place an order quoting the below part number.
Used to connect the GasClam 2 to the computer.
Contact us to place an order quoting the below part number.
Rechargeable battery pack for GasClam 2.
Contact us to place an order quoting the below part number.
Used to turn the GasClam 2 on and off while you are at the GasClam 2, rather than having to do it at the computer.
Contact us to place an order quoting the below part number.
Sensor for GasClam 2.
Contact us to place an order quoting the below part number.
O-rings for the top section of the GasClam 2 and batteries.
Contact us to place an order quoting the below part number.
O-rings for the bottom section of the GasClam 2 and batteries.
Contact us to place an order quoting the below part number.
Removes the moisture from the gas sample.
Contact us to place an order quoting the below part number.
Battery charger for GasClam 2 batteries.
Contact us to place an order quoting the below part number.
Used within GasClam 2.
Contact us to place an order quoting the below part number.
Used within GasClam 2.
Contact us to place an order quoting the below part number.
Used within GasClam 2.
Contact us to place an order quoting the below part number.
Used within GasClam 2.
Contact us to place an order quoting the below part number.
Used within GasClam 2.
Contact us to place an order quoting the below part number.
Sensor designed for the Titan instrument.
Contact us to place an order quoting the below part number.
Designed for the use within MiniPID 2 sensor.
Contact us to place an order quoting the below part number.
Designed for the use within MiniPID 2 sensor.
Contact us to place an order quoting the below part number.
Designed for the use within MiniPID 2 sensor.
Contact us to place an order quoting the below part number.
Contains components and tools required for general service and calibration.
Contact us to place an order quoting the below part number.
Alternative sensor housing used to integrate the TVOC 2 into a pumped system. NOTE: Maximum pressure 300 mBar. Recommended flow 250 to 500 ml/min.
Contact us to place an order quoting the below part number.
Alternative sensor housing allowing the TVOC 2 to be bump tested from a remote location.
Contact us to place an order quoting the below part number.
Used to adjust parameters and is needed throughout the calibration routine.
Contact us to place an order quoting the below part number.
Used to present clean air to the TVOC 2 sensor.
Contact us to place an order quoting the below part number.
This kit provides a spare detector module and number of accessories.
Contact us to place an order quoting the below part number.
Used to enable access to the internal service module.
Contact us to place an order quoting the below part number.
Filters the gas sample.
Contact us to place an order quoting the below part number.
Filters the gas sample.
Contact us to place an order quoting the below part number.
Stops airborne dirt, debris and water ingress from entering the system.
Contact us to place an order quoting the below part number.
This kit includes: hydrophobic filter, luer, label, installation instructions.
Contact us to place an order quoting the below part number.
Luer is attached to the front of the Falco & Falco TAC instrument. The hydrophobic fIlter is then attached to the luer fitting to prevent the ingress of water and moisture.
Contact us to place an order quoting the below part number.
Fitting between the Falco & Falco TAC pumped instrument and the hydrophobic filter.
Contact us to place an order quoting the below part number.
Attaches to the Luer fitting to prevent the ingress of water and moisture.
Contact us to place an order quoting the below part number.
Protects the instruments by filtering debris and water ingress.
Contact us to place an order quoting the below part number.
A kit of all the replacement O-rings you may need.
Contact us to place an order quoting the below part number.
Sits inside the Falco Sensor Cover.
Contact us to place an order quoting the below part number.
Fitted to the side of the Falco / Falco TAC Pumped instruments.
Contact us to place an order quoting the below part number.
Used to protect the MiniPID 2.
Contact us to place an order quoting the below part number.
The O-ring sits in the O-ring holder.
Contact us to place an order quoting the below part number.
The O-ring sits in the O-ring holder.
Contact us to place an order quoting the below part number.
The O-Ring holder is placed inside the Sensor Cover.
Contact us to place an order quoting the below part number.
Connects directly to the sensor housing of Falco Diffused.
Contact us to place an order quoting the below part number.
Firmly grips a pocket, collar or belt ensuring the Cub remains attached to you.
Contact us to place an order quoting the below part number.
Ensures seal integrity of the PID sensor.
Contact us to place an order quoting the below part number.
Ensures seal integrity of the PID sensor.
Contact us to place an order quoting the below part number.
PTFE filter blocks the ingress of water. The PTFE filters should be checked regularly to ensure best ongoing performance.
Contact us to place an order quoting the below part number.
PTFE filter blocks the ingress of water. When replacing the PTFE filter we recommenced you also change the O-rings.
Contact us to place an order quoting the below part number.
Cable to connect the docking station to an US mains socket.
Contact us to place an order quoting the below part number.
Cable to connect the docking station to an UK mains socket.
Contact us to place an order quoting the below part number.
Cable to connect the docking station to an EU mains socket.
Contact us to place an order quoting the below part number.
Cable to connect the docking station to an Australian mains socket.
Contact us to place an order quoting the below part number.
The docking station charges the Cub and Cub TAC instrument. There are three variants available: Charge Docking Station, Charge Docking Station + Data Download and Charge Docking Station + Data Download + Calibration.
Contact us to place an order quoting the below part number.
Allows the Cub docking station to be joined together and evenly spaced whilst securing multiple docking stations to the surface.
Contact us to place an order quoting the below part number.
Ensures calibration gas is presented to the MiniPID sensor evenly and at ambient air pressure. Allows connection to a typical 1/4
Contact us to place an order quoting the below part number.
Allows direct connection between the Cub docking station and the computer.
Contact us to place an order quoting the below part number.
Designed to safely break the glass tip off the benzene tube and stores it in the container.
Contact us to place an order quoting the below part number.
Designed to hold the benzene tubes securely onto the end of the Tiger Select.
Contact us to place an order quoting the below part number.
Ensures rapid detection and selective measurement of benzene and attaches to the Tiger Select via the tube holder.
Contact us to place an order quoting the below part number.
Used for MiniPID 2 10.0 eV Sensor. Found in Tiger Select, Cub TAC and can also be used in Tiger with 10.0 eV configuration.
Contact us to place an order quoting the below part number.
Designed for use within the ION Science PID sensor.
Contact us to place an order quoting the below part number.
Designed for use within the ION Science PID sensor.
Contact us to place an order quoting the below part number.
Protects your instrument from damage during general use.
Contact us to place an order quoting the below part number.
Offers up to 24 hours of continuous use.
Contact us to place an order quoting the below part number.
Used to protect the instrument from debris and water ingress.
Contact us to place an order quoting the below part number.
The probe seal sits in the filter clamp to keep it air tight.
Contact us to place an order quoting the below part number.
Used to make an air tight seal ensuring all gas passes through the PTFE filter.
Contact us to place an order quoting the below part number.
For use with the charge cradle, allows direct connection with UK, US, EU and AUS power sockets.
Contact us to place an order quoting the below part number.
Ensures the filter clamp is held in place ensuring a leak tight seal.
Contact us to place an order quoting the below part number.
Filter clamp holds the PTFE filter in place and ensures an air tight seal in conjunction with the O-ring.
Contact us to place an order quoting the below part number.
Screws into the exhaust port of the instrument allowing gas to be captured into a sample bag via typical 1/4 ID pipe.
Contact us to place an order quoting the below part number.
Can charge a Tiger lithium ion battery in just 6.5 hours. It can charge battery packs separately or connected to the instrument.
Contact us to place an order quoting the below part number.
Connects to a typical 1/4" ID calibration pipe when calibrating using a gas flow regulator. NOTE: Not to be used with a demand flow regulator.
Contact us to place an order quoting the below part number.
Allows VOC readings from the Tiger to be logged to a separate RS232 device.
Contact us to place an order quoting the below part number.
Fast direct connection between the Tiger instrument range and a computer.
Contact us to place an order quoting the below part number.
Convenient storage for the Tiger instrument range. Contains pre-cut foam inserts allowing the instrument, charger and accessories to be stored.
Contact us to place an order quoting the below part number.
The probe attaches easily and securely to the end of the instrument.
Contact us to place an order quoting the below part number.
Rugged case made to accommodate a gas cylinder and accessories.
Contact us to place an order quoting the below part number.
The carbon filter removes VOC gases from ambient air allowing instruments to be zero'd.
Contact us to place an order quoting the below part number.
The sensor seal is placed on the sensor cover of the Tiger models.
Contact us to place an order quoting the below part number.
The screw is used to keep the sensor cover attached to the back of the Tiger models.
Contact us to place an order quoting the below part number.
The sensor cover is screwed to the back of the Tiger models to protect the MiniPID 2.
Contact us to place an order quoting the below part number.
The lamp spring ensures the lamp stays tightly coupled with the electrode stack.
Contact us to place an order quoting the below part number.
The 11.7 eV lamp is an internal element to the ION Science PID sensor and is specifically designed for use only within ION Science PID.
Contact us to place an order quoting the below part number.
ION Science Inc.
4153 Bluebonnet Dr.
Stafford, Texas 77477
Tel: +1 (877) 864-7710
info@ionscienceusa.com
© 2026 Ion Science USA. Ion Science is registered trademark on Ion Science Ltd
Fill out the form below and our team will get back to you shortly.
Diffusion Fixed Gas Detection Device
A diffusion gas detection device works, as the name suggests, on the diffusion principle. The sensor is exposed to the ambient air and will measure the gas by means of the diffusion principle. Diffusion means proportional spread of molecules over the available space (from high concentration to low concentration). This also means that a diffusion gas detection device is only able to measure the concentration of gases at the location where the device is located. Since there is no forced flow of the gas to be measured, this device is not suitable for taking measurements remotely, but they do accurately identify what’s present in a given location.
Pumped Fixed Gas Detection Device
Pumped instruments are equipped with a built-in sampling pump. This means that the device is constantly drawing in gases. A sampling hose may be connected to extend the reach. This means that you can take a measurement from a safe distance so you have an idea of which gases will be present in which concentration before you are exposed to this environment. This allows you to make an appropriate risk analysis and make the right strategy and PPE choices based on the measurement results. By positioning the measuring hose correctly, you can also make a correct measurement at different heights to chart all risks.
Hub Spot Submit CV form
Register your instrument placeholder for Hub Spot Form
Request a quote — HubSpot form
Please scroll to compare more OEM Sensors
Please scroll to compare all OEM Gas Sensors, tick to hide sensors to compare the most suitable variants.
| Hide | ||||||||
|---|---|---|---|---|---|---|---|---|
| Comparative
specifications |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Sensor Variant |
MiniPID 2 PPM WR VOC Sensor |
MiniPID 2 PPM VOC Sensor |
MiniPID 2 PPB WR VOC Sensor |
MiniPID 2 PPB VOC Sensor |
MiniPID 2 HS VOC Sensor |
MiniPID 2 10.0 eV VOC Sensor |
MiniPID 2 11.7 eV VOC Sensor |
MiniPID 2 PPB XF Sensor |
| Electrode Stack Colour | Blue | Blue | White | White | Red | White + Gold Spot | White | White + Filter |
| Minimum Detection Limit | 500 ppb | 100 ppb | 20 ppb | 1 ppb | 0.5 ppb | 5 ppb | 100 ppb | 1 ppb |
| Range | 0 to >10,000 ppm | 0 to 4000 ppm | 0 to >200 ppm | 0 to >40 ppm | 0 to >3 ppm | 0 to >100 ppm | 0 to >100 ppm | >40 ppm |
| Response Time T90 (s) | <3 | <3 | <8 | <8 | <12 | <8 | <8 | <12s |
| Sensitivity | >0.4 mV/ppm @ 100ppm | Â >0.65 mV/ppm @ 100 ppm | Â >5 mV/ppm | Â >30 mV/ppm | Â >600 mV/ppm | Â >15 mV/ppm | Â >1 mV/ppm | >30 mV/ppm |
| Lamp Energy | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.0 eV | 11.7 eV | 10.6eV |
| Product Details | Product Details | Product Details | Product Details | Product Details | Product Details | Product Details | Product Details |