Setting the standards for headspace sampling by using PID

 

6th August 2020

Download Application Article

The responsiveness of ION Science MiniPID Gas Sensor to virtually all VOCs has seen the sensor become the accepted for initial site entry assessment, ensuring optimal detection of unknown and often toxic or hazardous chemicals found at hazardous waste sites and chemical emergencies. The speed and accuracy of modern PID equipment means that many worker and community safety concerns during initial and ongoing operations can be effectively assessed and monitored based on real-time field data, with many users around the world standardising on ION Science PIDs.

The end of the 1970s saw the advent of the US Environmental Protection Agency’s (EPA’s) Chemical Spill and Superfund programs to address chemical spill emergencies and the nation’s uncontrolled hazardous waste sites. A key primary decision that site assessment personnel had to make in every case was the establishment of “safe” and “work” zones and the coordination of levels of protective equipment that would be required to protect workers from the chemical seeping out from buried or loose, rusting and leaking drums and the protection of those working and living around such environmental incidents. Reliable site entry procedures had to be developed.

The work to develop site entry procedures was a cooperative venture between EPA, their contractor from Ecology and Environment, Dave Dahlstrom, and HNU Systems’ Geoff Hewitt (CEO of Ion Science’s US office). An industry grew up around these procedures as contractors sought to rent/acquire reliable and effective detection equipment for site assessment work. One of the first of these was Hazco Services which grew rapidly renting PIDs and other instruments for site assessments. At the time the HNU PI101 was the only commercial available PID.

As more and more chemical spill incidents occurred and uncontrolled chemical sites were discovered and designated hazardous, efforts to characterise these sites generated increasingly larger numbers of air, soil and water samples. By the mid 1980s, EPA’s Certified Lab Program facilities were stretched beyond capacity, and clean-up actions were often delayed for months. To address the problem, EPA developed field screening procedures that capitalised on the ability of PID-use methods to quantify, within limits, the degree of VOC contamination present in each soil/water/air sample collected.

These procedures were effective in minimising the number of samples submitted for lab analysis by eliminating samples that were ‘clean’ and also those that were contaminated so heavily as to present problems by contaminating the laboratory environment, personnel, and the expensive and sensitive analytical equipment. As EPA moved into the leaking underground storage tank arena, PIDs once more asserted themselves as the detection unit of choice for headspace screening of soil and ground water samples and work area safety monitoring.

setting_the_standard_for_headspace_sampling_by_using_ion_science_pid

As PID technology has continued to develop, speed and accuracy have continued to improve, to the point now where many areas of the US will allow site closure in the field. One state, Maine, decided to allow closure of certain types of sites based on PID data, but later found significant differences in results depending on the type of PID used. In order to level the playing field, Maine decided to limit PID use to those models their Technical Services branch had evaluated and assigned a ‘Calibration Set Point’. This set point is used as a multiplier to correct the unit’s reading to the actual value as determined and verified by the Maine Department of Environmental Protection (DEP).

Set points varied from as high as 400 for the HNU PI101 to 260 for the MiniRae 3000, down to 130 for the ION Tiger series, all referenced to Maine’s normalised value of 100, with a bigger set point equating to a bigger inaccuracy. Maine DEP and many other users have taken the decision to switch over to the ION Science PID. ION Science provide a portfolio of handheld, fixed and portable photoionisation (PID) detection instruments for the rapid, accurate detection of volatile organic compounds (VOCs). Independently verified as the best performing PID technology on the market, ION Science Tiger instruments are proven to achieve superior results over all competition for accuracy, speed, reliability and optimal performance in humid environments.

Download Application ArticleView All Application Articles

For more information on PID gas detectors, please contact us on:

info@ionscience.com

or telephone: +44 (0) 1763 208 503.

Application Article

Everything you need to know about setting the standards for headspace sampling by using ION Science PID

Our Application Articles are available to download below, they provide you with key information on the exposure limits and the locations of where potentially harmful gases can occur within your application and share information on the gas detection monitoring techniques and equipment that can help you manage gas detection in the workplace.

Headspace Sampling By PID

Download Application Article

Related Application Articles

Methyl bromide as fumigant for international transports

Methyl bromide is a is an odourless, colourless gas most often used as a fumigant. About 70% of methyl bromide produced in the United States goes into pesticidal formulations.

View Details

PID in Construction

PID in construction is a great way to identify VOCs being emitted from contaminated development land prior to redevelopment.

View Details

VOCs In The Food And Beverage Industry

Where are VOCs found in the food and Beverage industry and why do we need to monitor them. Also do you know how to detect such toxic gases?

View Details

Download your copy of the Application Article

Please complete the form below to download the Application Article.