Gas Detector Accessories
Please select your ION Science Gas Detector or Leak Detector from the drop down list to view all available accessories for your instrument.
Home » Gas and Leak Detectors » Customer Support » Accessories
Please select your ION Science Gas Detector or Leak Detector from the drop down list to view all available accessories for your instrument.
Register your instrument now to extend your warranty to up to five years!
The pen provides simple, quick reassurance that your detector is responding to the presence of VOCs prior to use.
The lanyard can prevent you from accidentally dropping your Tiger XT range instrument as it will be tethered to your wrist.
Used for hard to reach areas such as confined spaces.
Used for hard to reach areas such as confined spaces.
Contains a lamp cleaning kit, PTFE filters and other components required for general user servicing.
A 100 ppm isobutylene gas cylinder for accurate calibration and verification of instrument performance.
This car charger lead plugs into the Tigers charge cradle allowing the instrument to be charged from a standard 12Vdc cigar/cigarette lighter socket.
The demand flow regulator draws gas when demanded by an instrument. Used for Cub, Tiger, Tiger LT, Tiger Select & Falco Pumped.
The 1m flexi probe enables greater flexibility for the detection of VOCs in hard to reach places.
This gas is used to calibrate Tiger XT, Tiger XTL, Tiger XT Select and Cub.
Used to clean the lamp within the MiniPID sensor to remove dirt, grease and grime from the lamp window ensuring optimal performance.
Allows safe, easy removal of the stack from the PID sensor.
Tel: +44 (0) 1763 208 503
info@ionscience.com
© 2023 Ion Science UK. Ion Science is registered trademark on Ion Science Ltd
Diffusion Fixed Gas Detection Device
A diffusion gas detection device works, as the name suggests, on the diffusion principle. The sensor is exposed to the ambient air and will measure the gas by means of the diffusion principle. Diffusion means proportional spread of molecules over the available space (from high concentration to low concentration). This also means that a diffusion gas detection device is only able to measure the concentration of gases at the location where the device is located. Since there is no forced flow of the gas to be measured, this device is not suitable for taking measurements remotely, but they do accurately identify what’s present in a given location.
Pumped Fixed Gas Detection Device
Pumped instruments are equipped with a built-in sampling pump. This means that the device is constantly drawing in gases. A sampling hose may be connected to extend the reach. This means that you can take a measurement from a safe distance so you have an idea of which gases will be present in which concentration before you are exposed to this environment. This allows you to make an appropriate risk analysis and make the right strategy and PPE choices based on the measurement results. By positioning the measuring hose correctly, you can also make a correct measurement at different heights to chart all risks.
Request a quote — HubSpot form
Please scroll to compare more OEM Sensors
Please scroll to compare all OEM Gas Sensors, tick to hide sensors to compare the most suitable variants.
Hide | |||||||
---|---|---|---|---|---|---|---|
Comparative
specifications |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Sensor Variant |
MiniPID 2 PPM WR VOC Sensor |
MiniPID 2 PPM VOC Sensor |
MiniPID 2 PPB WR VOC Sensor |
MiniPID 2 PPB VOC Sensor |
MiniPID 2 HS VOC Sensor |
MiniPID 2 10.0 eV VOC Sensor |
MiniPID 2 11.7 eV VOC Sensor |
Electrode Stack Colour | Blue | Blue | White | White | Red | White + Gold Spot | White |
Minimum Detection Limit | 500 ppb | 100 ppb | 20 ppb | 1 ppb | 0.5 ppb | 5 ppb | 100 ppb |
Range | 0 to >10,000 ppm | 0 to 4000 ppm | 0 to >200 ppm | 0 to >40 ppm | 0 to >3 ppm | 0 to >100 ppm | 0 to >100 ppm |
Response Time T90 (s) | <3 | <3 | <8 | <8 | <12 | <8 | <8 |
Sensitivity | >0.4 mV/ppm @ 100ppm | Â >0.65 mV/ppm @ 100 ppm | Â >5 mV/ppm | Â >30 mV/ppm | Â >600 mV/ppm | Â >15 mV/ppm | Â >1 mV/ppm |
Lamp Energy | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.0 eV | 11.7 eV |
Product Details | Product Details | Product Details | Product Details | Product Details | Product Details | Product Details |
Register your instrument placeholder for Hub Spot Form