Falco fixed VOC monitors
Ion Science announces the launch of its Falco series of fixed continuous VOC monitors for the on-going protection of workers operating in hazardous industrial environments.
Incorporating first of a kind ‘typhoon’ technology for added reliability, Falco is specifically designed to work in condensing atmospheres and extreme weather conditions! Falco boasts fast response times and several innovative design features. The instrument’s ‘typhoon’ technology prevents condensation forming on the sensor and removes the risk of the system short-circuiting – making it ideal for use in harsh weather and high humidity.
The new VOC monitor is simple to operate, while an externally located Intrinsically Safe (IS) sensor facilitates quick and easy servicing without the need for a hot work permit.
About the Falco
Falco is the latest generation of fixed VOC detectors that continuously detect a wide range of volatile organic compounds (VOCs) using patented photoionisation detection (PID) technology.
Unique to this fixed VOC detector is its revolutionary ‘typhoon technology’ safeguarding the PID sensor from condensing moisture for added reliability in severe weather conditions. In addition, the PID sensor incorporates patented Fence Electrode Technology, which virtually removes the effects of airborne humidity and protects from contamination.
The Falco VOC detector gives you cutting-edge performance; reliability, accuracy and results you can trust so you can be sure workforce and plant receive on-going maximum protection. With its humidity resistance and anti-contamination design drift is minimised and run-time extended, saving both time and cost to your business.
Offering the ultimate in safety, Falco eliminates false readings found with other competing PID technology. Its multi-coloured LED status display can be seen from a distance of twenty metres in sunlight ensuring you are clearly alerted to hazards present.
Falco has an externally located Intrinsically Safe sensor for quick and easy servicing without the need for a hot work permit. Dual certification allows Falco to be serviced and calibrated in a hazardous environment without having to remove power.
Simple to operate the Falco fixed VOC detector has an intuitive user interface. It has five magnetic switches with LED confirmation, a high contrast OLED screen and graphical interface ensuring installation and servicing are both quick and easy.
RS485 (Modbus®), 4-20 mA and Relay outputs are standard for all models. The Relay outputs are configurable for either high and low alarms, fault conditions or test cycle synchronisation.
The Falco fixed VOC detector offers the ultimate in flexibility and can be purchased as one of four detection ranges in either a pumped or diffused variant. With a diffused model, servicing costs are kept to a minimum with no pump to maintain.