Titan 2
Monitor and sample benzene with world leading benzene detection technology.
Titan 2 benzene gas monitor incorporates the NEW MiniPID T2 10.0 eV Sensor which offers improved sensitivity, reliability and overall performance. The unique sampling method eliminates interfering gases such as toluene, xylene and methane providing you with accurate benzene concentration readings you can rely on.
Features
Titan 2 offers a world leading solution for the detection of benzene, providing precise detection at levels as low as 0.02 ppm (20 ppb) and as high as 20 ppm within 60 seconds. Titan 2 benzene gas monitor has been specifically engineered to analyse airborne dangers and can be utilised to evaluate the efficiency of purification or vapour recovery systems/units (VRU).
Titan 2 benzene gas monitor has obtained certification for use in ATEX zoned environments and locations. Furthermore, the enclosure is IP65 rated, offering reliable protection against the intrusion of dust and water.
Key Features
- New MiniPID T2 10.0 eV Sensor – Unique to Titan 2.
- Low Detection Limit – Can detect benzene down to 0.02 ppm (20 ppb).
- IP65 – Protection against a range of atmospheric conditions.
- Interchangeable Service Module – plug and play cartridge.
- 4-20 mA & RS485 Communication Options – Connect to your own control system.
Typical Industries & Applications
- Oil & gas
- Bulk storage facilities
- Chemical manufacturing and processing
- Asphalt production
2 Year Extended Warranty Available
Step 1) Purchase an ION Science Titan 2 benzene gas detector
Step 2) Register your instrument here within one month of purchase
Step 3) Receive a 2 year extended warranty certificate!
Industrial Environments
Benzene is a highly toxic and carcinogenic chemical that can cause both short-term and long-term effects on workers who are exposed to it. The most significant health risks associated with long-term benzene exposure is the development of leukemia, specifically acute myeloid leukemia (AML).
Titan 2 delivers unrivalled accuracy and sensitivity in benzene detection and is ideal for use in a variety of sectors such as oil and gas, bulk storage facilities, chemical manufacturing and processing and asphalt production.
What’s Included?
- Titan 2 Benzene Monitor
- Titan 2 Handles
- Transit Strap
- Transit Strap Screws
- Accessory Kit (9 Way Connector, 5 Way Connector, 2 mm Allen Key, 2.5 mm Allen Key, 3 mm Allen Key, Actuation Magnet)
- Hydrophobic Filter
- Gland Port Plug (For Transportation)
- Documentation (Safety Notice, Responsibility of Correct Use, Calibration Certificate)
Technical Specification
Specification | Value |
Sensor Type | MiniPID T2 10.0 eV Sensor |
Sensitivity | Benzene specific within typical petrochemical matrix |
Detectable Range | 0.02 ppm – 20 ppm |
Measuring Frequency | One Minute |
Lower Level of Detection | 0.02 ppm (20 ppb) (10 ppb resolution) |
Accuracy | +/- 50 ppb or +/- 10%, whichever is greater* |
Temperature Stability | Internally heated |
Flow Rate | Sample flow rate ≥ 100 ml/min |
Display | Graphic BW LCD 64 x 128 pixels with backlight Bright LEDs for normal operation, fault and alarm Two magnetic switches for menu operation |
Operating Temperature | Recommended operating range of -20 oC to +50 oC (-4 oF to +122 oF) for optimum performance** |
Approvals | 4FTZU 14 ATEX 0172X IECEx FTZU 14.0030X QPS LR1621-1 Ta= -20 oC to +55 oC |
Ingress Protection Rating | IP65 |
Humidity | 0 – 99 % RH |
Minimum Service Period | 6 months – PID lamp, electrode stack, inline filter, VRV restrictor, Hydrophobic & carbon filter replacement 12 months – PID lamp, electrode stack, inline filter, VRV restrictor, hydrophobic & carbon filter, Airsep filter |
Cable Entry | Two ¾ NPT gland threads |
Power Requirements | Vin (nom) 24 V DC @ 3.2 A (recommended) Vin (max) 32 V DC @ 2.4 A Vin (min) 19 V DC @ 4.0 A |
Communication | Isolated 4-20 mA output Isolated RS 485 Modbus connection via ASCII or RTU (simplex/half duplex or fully duplex) Micro USB (PC Software) |
Data Storage | On board MMC, minimum of six months (2GB) |
Relay Output | Two isolated outputs, voltage free, 24 v DC @ 1.25 A |
Weight and Dimensions | 15 kg (33 lbs) 219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.) |
Gas Sample Line | 10 m max length, PTFE, 6 mm OD, 4 mm ID |
*± 10 ppb for readings ≤ 0.1 ppm
**+55 oC = ± 20% accuracy
Video Library
Downloads
For supporting resources for the Titan 2 Benzene Gas Monitor, please see below.
Titan 2 Benzene Gas Monitor Accessories and Replacement Parts
There are a number of accessories and replacement parts available for the Titan 2 Benzene Gas Monitor, which can be found below. Please contact us if you would like more information or to place an order.
Hydrophobic Filter
Used to prevent the ingress of water and dust.
Part Number: A-875417
Carbon Filter Assembly (With Connectors)
Used to prevent the ingress of water and dust.
Part Number: A-875505
FAQs
If you have any questions related to the Titan 2 Fixed Benzene Monitor, please view our frequently asked questions.
Titan 2 Benzene Gas Monitor Enquiry Form
Please complete the form below and a member of our team will contact you shortly.
Global Distributors
All ION Science distributors are trained to the highest standards to provide you with access to our product portfolio locally, along with the best possible service and support. Find your local representative.