Tiger LT
Portable VOC gas detector
The Tiger LT is a portable VOC gas detector that works as an entry-level handheld, portable VOC gas detector. This portable VOC detector that provides you with fast, accurate & reliable results, however challenging your environment.
The Tiger LT portable VOC gas detector is a variant of the hugely popular Tiger, but low on cost and high on performance. The portable VOC gas detector utilises revolutionary, patented photoionisation detection (PID) sensor technology with humidity resistance. The anti-contamination design provides market-leading accuracy and run-time for any gas detection scenario.

Features
The leading technology of our Tiger LT Portable gas detector provides the most accurate, reliable detection of VOCs giving the right results whilst maximising field time.
The Tiger LT portable VOC gas detector offers simple, one-handed operation even when wearing the thickest of gloves. Its rugged yet portable design and protective, removable rubber boot can withstand the harshest environments.
The large, clear backlit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when the light is low.
Other instruments in the Tiger portable VOC gas detector range are the Tiger VOC gas detector and the Tiger Select for total aromatic compounds, including benzene.
Ultimate Performance
- Accurate results across all environments from 0 – 5000 ppm
- Patented humidity resistance to 99% RH – no compensation needed
- Anti-contamination design minimises drift and extends run time
- Fastest 2-second response time and rapid clear down
- Li-ion battery for up to 24 hours continuous operation
- 6.5 hours battery charge time maximises uptime
- Batteries field replaceable, even in explosive environments
Ultimate Safety
- 95 dBA, bright LED and vibration alarms alert you to gases present
- Intrinsically safe; meets ATEX, IECEx, UL and CSA standards
Ultimate Flexibility
- Simple icon driven menu requires minimal user training
- Filters and lamps replaceable in minutes
- Li-ion battery for up to 24 hours continuous operation
- Portable size to detect VOC gasses virtually anywhere
Technical Specification
Specification | Value |
---|---|
Minimum Resolution* | 0.1 ppm |
Maximum Reading | 5,000 ppm |
Response Time | T90 < 2 seconds |
Accuracy* | ± 5% display reading ± 1 digit |
Linearity* | 5% display reading ± one digit |
Intrinsically Safe Approvals | II1GExiaIICT4Ga Tamb = – 15 °C =Ta =+45 °C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1. Class 1 Division 1. Approval for groups A, B, C & D, T4. |
Battery Life | Li-ion: life up to 24 hours continual use |
Lamps | 10.6 eV Krypton PID lamp (standard) |
Data Logging* | Push-to-log, 128 zones, 80,000 data points |
Calibration | Standard calibration 100 ppm isobutylene Custom calibration capability |
Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder selectable vibrating alarm |
Flow Rate | ≥ 220 ml/min in ambient conditions (with blocked flow alarm) |
Temperature | Operating: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe) Humidity: 0-99% RH (non condensing) |
Protection | Designed to IP65 (heavy rain) C E 1180 EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A |
Weight & Dimensions | Instrument (with probe) Width: 91.4 x Height: 370 x Depth: 61 mm (3.59 x 14.56 x 2.4”) Instrument weight 0.75 kg |
All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on isobutylene calibration at 20 ˚C, 90% RH and 1000 mBar
*Model dependant.

What our customers say
View Case StudyView All Case StudiesView All Testimonials”“The company that installed the odour control system at the waste transfer station recommended we use Ion Science’s Tiger PID to measure VOCs from the three outlet ports to help assess utilisation of the carbon filter media.”
Yannic Bearder, Guernseys waste stationSenior Environmental Monitoring Technician

What our customers say
View Case StudyView All Case StudiesView All Testimonials”ION Science Tiger PIDs are a robust and reliable product for detecting VOCs during fire investigations.
Ian Mullen, Station ManagerMerseyside Fire & Rescue Service, Incident Investigation
Video Library
Downloads
Supporting downloads for the Tiger LT portable VOC gas detector can be found below.
Tiger LT Portable VOC Gas Detector Accessories and Replacement Parts
A number of accessories and replacement parts are available for the Tiger LT portable VOC gas detector, found below. Please contact us for more information or to place an order.
FAQs
Frequently asked questions related to the Tiger LT portable VOC gas detector can be found below. If you need further assistance please contact us.
Tiger LT portable VOC Gas Detector Inquiry Form
Please complete the form below and a member of our team will contact you shortly.
Global Distributors
All ION Science distributors are trained to the highest standards to provide you with access to our product portfolio locally, along with the best possible service and support. Find your local representative.