Tiger VOC detector resistant to humidity

Tiger VOC for humidity

Spanish geological and environmental consultancy, GeoAmbient, is using a Tiger as part of its subsoil investigation activities.

Tiger VOC for humidity – Tiger, chosen for its humidity resistant, ATEX accredited MiniPID 2 PID sensor, the high performance, handheld VOC detector is being used across outdoor sites, on a year-round basis.

Albert Sabanès comments: “At GeoAmbient, we keep updated on the latest technical developments for our industry through regular communication with suppliers, the internet and by maintaining professional relationships. As a result of this on-going research, we became aware of the benefits offered by the Ion Science Tiger system, including its very good, market-leading MiniPID 2 sensor. We conduct subsoil investigation so it is very important to have in situ information of polluted soils to help us decide the best place to take a sample. Our technical teams work on outdoor sites during all weather conditions so the Tiger’s humidity resistant sensor was the most important feature for our business. Of course, the anti-contamination design was also vital to avoid cross pollution and ensure data integrity.”

About the Tiger

The Tiger handheld VOC detector is a revolutionary handheld gas detection instrument for the rapid, accurate detection of volatile organic compounds (VOCs) within the harshest of environments.

Tiger incorporates Ion Science patented photoionisation detection (PID) sensor technology with humidity resistance and anti-contamination design, proven to dramatically extend run time in the field.

A robust VOC detector Tiger provides a dynamic detection range of 0 to 20,000 parts per million (ppm) with a minimum sensitivity of 0.001ppm (1 ppb), offering the widest measurement range of any other VOC detector on the market.

This handheld VOC detector has the fastest response time on the market of just two seconds and is just as quick to clear down. The instrument can be connected directly to a PC via the USB offering extremely fast data download capabilities.

Tiger has been designed for the safe replacement of batteries in hazardous environments. Long-life rechargeable Li-ion batteries give up to 24 hours of use. Fast battery charging allows the instrument to be fully charged in 6.5 hours, while 8 hours of use can be achieved from 1.5 hours charge.

Low-cost filters and lamps can be easily changed in seconds, minimising instrument downtime. Inexpensive disposable parts mean the Tiger VOC detector has the lowest running costs on the market.

Tiger is a fully upgradeable VOC detector with multiple functions to choose from. A base unit can be upgraded with data logging, health and safety and ppb options, remotely, without needing to be returned to the factory.

Tiger offers simple, one-handed operation for easy VOC detection. Its rugged design and protective, removable rubber boot withstand the harshest environments.

The large, clear back-lit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas.

Ready to use on start-up the Tiger VOC detector needs no complex set up procedures via a PC to perform basic functions. Its simple-to-use software features require minimal user training.

Tiger uses the same PID sensor technology found within all Ion Science handheld, personal and fixed VOC detectors. This ground-breaking PID technology is widely used and trusted by major gas detection manufacturers worldwide.