What our customers say
See why ION Science are the chosen experts in manufacturing trusted gas monitoring equipment, don’t take our word for it, find out from who we’ve worked with.
Home » Gas and Leak Detectors » Resource Centre » Case Studies
See why ION Science are the chosen experts in manufacturing trusted gas monitoring equipment, don’t take our word for it, find out from who we’ve worked with.
ExR-1 Robot incorporated with Falco For Autonomous Gas Detection, designed to detect VOCs in remote unmanned facilities within the oil and gas industry.
Handheld, portable photoionisation detectors help Merseyside Fire and Rescue, to detect volatile organic compounds from ignitable liquids.
Russian Bioanalytical Laboratory are using a handheld instrument to monitor for nitrogen and argon leaks as part of pivotal gas management system.
Tabib Toxic Waste Services purchased Tiger LT portable VOC detector from ION Science to monitor for Volatile Organic Compounds (VOCs) in box containers.
Fixed continuous PID which monitors pump seals for leaks of different grades of solvents in the C6-C9 aromatic compound range.
Fixed continuous PID which monitors pump seals for leaks of different grades of solvents in the C6-C9 aromatic compound range.
IGE Consulting, are using the Tiger LT handheld photoionisation detector (PID) to provide comprehensive risk assessments of on-site contamination.
Lone Star Hazmat Response Team use Tiger LT to detector for their emergency spill response specialists to ensure the safety of first responders.
Ninewells hospital are using an ION Science Tiger to adhere with the Human Fertilisation and Embryology (HFEA) regulations for air quality in tissue laboratories and to ensure optimum culture conditions for embryos.
States Works are using the Tiger LT portable PID to measure VOC levels being emitted from an odour control system at their waste transfer station.
Global Plasma Solutions use TVOC 2 for Indoor Air Quality, ION Science products are revolutionising health and safety across various industries by improving IAQ.
Air Liquide Electronics, purchased the GasCheck G leak detector. Chosen for the robust, reliable and upgradeable design, used to check for gas leaks after high pressure cylinder changes.
Australian environmental consultancy, JBS&G adds another Tiger PID detector to its range of gas detection instrument for major contaminated land projects
USA-based Lakeshore Environmental chooses TigerLT PID for humidity resistance and value for money while they monitor for volatile organic compounds (VOCs).
US Geochemical uses Tiger as part of Oil and Gas exploration.
Massachusetts-based CEC Inc choose latest instrument for competitive price point, durable design, anti-contamination and humidity resistance.
Additional handheld PID instruments which help protect military personnel are chosen for compact & robust design, reliability and ease of use
30 Tiger VOC gas detectors are purchase by Harbin Metro Group to detect VOCs within luggage and bags.
ION Science’s unobtrusive personal Cub PIDs provide reliable protection from hazardous gases and vapours at port of antwerp.
Handheld photoionization (PID) instrument used to monitor emissions from housekeeping products such as paints, adhesives and new furniture
Latest project forms part of successful tender by key distributor Amos Gazit for the design, supply and installation of a complete gas detection system.
ION Science has recently supplied 300 Tiger hand-held volatile organic compound (VOC) detectors to Germany’s Federal Office of Civil Protection and Disaster Assistance.
Site investigation geotechnical engineering, Southern Testing, has opted to use handheld VOC detectors to measure VOCs in the field.
Spanish geological and environmental consultancy, Geoambient, is using a Tiger PID from ION Science as part of its subsoil investigation activities.
Portable reliable PID technology ensures extended operation in tough environmental conditions with its humidity resistant and anti-contamination design.
NOC use personal detectors to reduce employees risk of exposure to essential chemicals used in a fume containment cabinet.
High-performance handheld PID chosen for anti-humidity design by leading Thai indoor air quality monitoring specialist as part of its audit programme.
Luxembourg police crime scene investigation (CSI) division uses Tiger VOC detector for all crime scene, fatal accident and arson investigation
Danish sewage treatment plant, continuous VOC monitoring of sewage lines helps avoid costly and time consuming clean-up of sludge
Hand held PID instrument helps ensure health & safety of project team – detecting hydrocarbon emissions that may arise during major clean-up operation
Brandursachenermittlung, purchased two Tiger volatile organic compound (VOC) detectors from ION Science for use as part of the fire investigation activities
Purolite Corporation China is using a Mercury Vapour Indicator (MVI) to protect their workforce from the ingestion of mercury.
Handheld PID instrument performance and support package is better than the competition says leading environmental sampling and monitoring specialist.
As part of an exciting research project led by the University of Catania, a Tiger PID has recently been integrated into a UAV drone.
Tiger PID instrument used as Fire Investigation Tool to work alongside Fire and Rescue Service search and rescue dog team.
Portable instruments chosen for rapid, accurate detection of volatile organic compounds to protect Tata Hitachi Paint Booth Workers.
Aurobindo ensure staff are protected from potential VOC exposure to achieve new levels of quality and safety by gas detection monitors.
© 2024 Ion Science India. Ion Science is registered trademark on Ion Science Ltd
Diffusion Fixed Gas Detection Device
A diffusion gas detection device works, as the name suggests, on the diffusion principle. The sensor is exposed to the ambient air and will measure the gas by means of the diffusion principle. Diffusion means proportional spread of molecules over the available space (from high concentration to low concentration). This also means that a diffusion gas detection device is only able to measure the concentration of gases at the location where the device is located. Since there is no forced flow of the gas to be measured, this device is not suitable for taking measurements remotely, but they do accurately identify what’s present in a given location.
Pumped Fixed Gas Detection Device
Pumped instruments are equipped with a built-in sampling pump. This means that the device is constantly drawing in gases. A sampling hose may be connected to extend the reach. This means that you can take a measurement from a safe distance so you have an idea of which gases will be present in which concentration before you are exposed to this environment. This allows you to make an appropriate risk analysis and make the right strategy and PPE choices based on the measurement results. By positioning the measuring hose correctly, you can also make a correct measurement at different heights to chart all risks.
Request a quote — HubSpot form
Please scroll to compare more OEM Sensors
Please scroll to compare all OEM Gas Sensors, tick to hide sensors to compare the most suitable variants.
Hide | ||||||||
---|---|---|---|---|---|---|---|---|
Comparative specifications | ||||||||
Sensor Variant | MiniPID 2 PPM WR VOC Sensor | MiniPID 2 PPM VOC Sensor | MiniPID 2 PPB WR VOC Sensor | MiniPID 2 PPB VOC Sensor | MiniPID 2 HS VOC Sensor | MiniPID 2 10.0 eV VOC Sensor | MiniPID 2 11.7 eV VOC Sensor | MiniPID 2 PPB XF Sensor |
Electrode Stack Colour | Blue | Blue | White | White | Red | White + Gold Spot | White | White + Filter |
Minimum Detection Limit | 500 ppb | 100 ppb | 20 ppb | 1 ppb | 0.5 ppb | 5 ppb | 100 ppb | 1 ppb |
Range | 0 to >10,000 ppm | 0 to 4000 ppm | 0 to >200 ppm | 0 to >40 ppm | 0 to >3 ppm | 0 to >100 ppm | 0 to >100 ppm | >40 ppm |
Response Time T90 (s) | <3 | <3 | <8 | <8 | <12 | <8 | <8 | <12s |
Sensitivity | >0.4 mV/ppm @ 100ppm | >0.65 mV/ppm @ 100 ppm | >5 mV/ppm | >30 mV/ppm | >600 mV/ppm | >15 mV/ppm | >1 mV/ppm | >30 mV/ppm |
Lamp Energy | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.6 eV | 10.0 eV | 11.7 eV | 10.6eV |
Product Details | Product Details | Product Details | Product Details | Product Details | Product Details | Product Details | Product Details |
Register your instrument placeholder for Hub Spot Form